University of Alberta
3D Reconstruction of Body Surface Topography with Stereo-Camera in Close-Range Using Artificial Intelligence
Abstract
dc:description.abstractAdolescent idiopathic scoliosis is a three-dimensional spinal disorder characterized by lateral curvature in the coronal and sagittal planes and vertebral rotation in the axial plane. One of the nonionizing radiation methods to diagnose and evaluate scoliosis involves analyzing surface topography of a patient’s back. Another approach is to use ultrasound to scan and capture the internal spine structure. To combine both non-radiation imaging methods for scoliosis, a device that integrated a portable stereo camera with an ultrasound scanner was proposed. Traditional surface topography capture requires an operator to stand at a specific distance and manually acquire the body images from multiple angles, but this method takes time. This thesis is focused on exploring more efficient techniques to reconstruct 3D surface topography simultaneously while performing an ultrasound spinal scanning. Two complementary methods were developed and evaluated for 3D reconstruction using motion tracking along spinal paths in close-range imaging scenarios with low-feature back textures. The first method combined 2D image stitching with neural network-based depth estimation. Partial images captured along the spine were aligned using two developed stitching algorithms: the Feature-Based Homography Stitching Algorithm and the Translation-Optimized Image Stacking Algorithm. The second algorithm performed better in 2D reconstruction, with an average relative error of 7.38%, compared to 20.35% for the first. The stitched image was then processed by a deep learning model to generate a depth map, resulting in a complete 3D reconstruction. For depth estimation, three pre-trained neural networks were used: Google HitNet, MiDaS, and Depth Anything. Among them, Depth Anything achieved the best performance, with a Chamfer distance of 0.0108 m, outperforming Google HitNet (0.0134 m) and MiDaS (0.0149 m). The second proposed method employed stereo depth mapping with positional tracking and Truncated Signed Distance Function (TSDF) volume fusion. A calibrated stereo camera captured depth maps for each frame while simultaneously recording its trajectory, and these depth maps were incrementally fused into a unified 3D model using a TSDF volume. Quantitative evaluation using the Chamfer Distance metric indicated that the stereo-TSDF method achieved superior geometric fidelity—approximately 0.0089 m compared to 0.0108 m for the stitching-neural approach. Additionally, the time required by clinicians to capture 3D reconstructions was reduced from an average of 3 minutes to just 30 seconds, making the proposed system approximately six times faster than traditional 3D reconstruction methods at further distances. As a result, the stereo-based volumetric fusion method was favored for its higher accuracy, more precise surface capture, and enhanced robustness to noise, thereby offering a promising solution for more efficient 3D reconstruction in clinical settings.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Software engineering & Intelligent systems
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ebrahimi Jouibari, Zahra
- Advisors dc:contributor.advisor
-
- Reformat, Marek
- Lou, Edmond
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/85656