Back to search

University of Alberta

Biomechanics of the Bone-Implant Interface: Computational Analysis of Insertion Dynamics and Vibration-Based Assessment of Interfacial Stability

Abstract

dc:description.abstract

The success of osseointegrated implants, such as dental implants and bone-anchored hearing system (BAHS) implants, is highly dependent on adequate primary stability and successful osseointegration. The primary objective of this thesis was to establish quantitative relationships between biomechanical factors, such as implant design and bone quality, and the mechanical behavior of the bone–implant interface (BII) in dental and BAHS applications. Specifically, this research investigated how these factors influenced implant insertion mechanics and interfacial stiffness, as quantified using a vibration-based implant stability measurement approach, and conducted a preliminary assessment of the feasibility of using this approach to monitor implant stability. A computational model was developed to simulate the dynamic process of implant insertion and was validated against experimentally measured insertion torque curves. The model was used to evaluate stress distributions in the material surrounding three implant designs. In vitro experiments using a controlled bone simulant and ex vivo porcine bone were subsequently conducted to quantify the effects of implant design and bone quality-related factors, including bone defects, bone density, cortical bone thickness and bone volume, on interface stiffness. Building on these benchtop studies, a clinical pilot study was conducted to evaluate the feasibility of using the vibration-based approach for the longitudinal assessment of dental implant stability. The computational model showed good agreement with the experimentally measured insertion torque curves. Stress peaks occurred where the implant flange compressed the surrounding material and where the thread dimensions increased substantially relative to the immediately preceding thread layer on the implant-tip side. In contrast, a stress trough was observed where the thread diameter and thickness were relatively small compared with those of the preceding thread layer. Moreover, a larger implant-to-osteotomy diameter ratio was associated with a broader stress distribution and higher stress magnitudes. Similarly, the benchtop experiments showed that a larger implant-to-osteotomy diameter ratio was associated with greater interface stiffness. The in vitro studies showed that bone density, cortical layer thickness, and bone volume were positively associated with interface stiffness, whereas the severity of bone defects was negatively associated with interface stiffness. It was further demonstrated that the vibration-based approach was sensitive to changes in bone defects, bone density, cortical layer thickness, and bone volume. In the clinical pilot study, the acceleration signals measured using the vibration-based approach were highly similar to those obtained in the benchtop experiments. Additionally, the BII stiffness values were significantly higher at the last available measurement than at the first available measurement. These findings provided preliminary evidence supporting the feasibility of using the vibration-based approach for the longitudinal clinical assessment of dental implant stability. Through computational modeling and experimental testing, this research established relationships between biomechanical factors and BII mechanics, including interface stiffness and peri-implant stress. These findings advance the understanding of bone–implant biomechanics and may support improved implant design, non-invasive implant monitoring, and, ultimately, the long-term success of osseointegrated implants.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pan, Boyu
Advisor dc:contributor.advisor
  • Westover, Lindsey (Biomedical Engineering)

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/85695

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Pan, Boyu. Biomechanics of the Bone-Implant Interface: Computational Analysis of Insertion Dynamics and Vibration-Based Assessment of Interfacial Stability. Doctoral thesis, University of Alberta, 2026. https://doi.org/10.7939/85695