Back to search

University of Alberta

Detector Response Simulation and Radon Trap Characterization for the NEWS-G Experiments

Abstract

dc:description.abstract

Direct searches for low-mass dark matter require detectors that combine sub-keV energy thresholds with extremely low intrinsic radioactivity and a reliable detector-response model. The NEWS-G experiment uses spherical proportional counters filled with light target gases to search for dark matter in the sub-GeV mass range. At these energies, both potential dark matter signals and background events can produce ionisation signals containing only a few electrons. Their statistical separation therefore depends not only on energy, but also on an accurate description of electron transport and detector response. In addition, radioactive contaminants such as radon can generate both prompt low-energy backgrounds in the detector and long-lived surface contamination. This thesis addresses these challenges through two studies: a 3D electron transport and space charge simulation for NEWS-G, and a room temperature radon-mitigation study based on silver-zeolite adsorption. The detector response study combines COMSOL electric field maps with Magboltz electron transport parameters to simulate electron drift and diffusion in S140. The simulation gives a reasonable description of the low-intensity laser drift time data, where only a small number of photoelectrons are produced in each pulse. However, clear discrepancies appear when the same simulation method is applied to the ³⁷Ar rise time data. To understand this difference, the high-intensity laser data recorded in the same run as the ³⁷Ar events are used to study space charges effect. This study shows that a non-negligible positive-ion population must be present and that the effective reduced ion mobility in the detector is likely lower than the value usually assumed from the literature, possibly because of impurities in the gas. Under the same detector conditions, ions produced by ³⁷Ar events would also drift more slowly and remain in the detector for longer than expected, so the ³⁷Ar-derived diffusion model may include space charge effects that are specific to the calibration run. Since this diffusion model is used to predict the timing distributions of low-energy signal and background events in the dark matter analysis, such effects can directly affect the response model used to set dark matter exclusion limits. The radon study uses a closed-loop gas system coupled to a 30 cm spherical proportional counter to test whether Ag-ETS-10 can efficiently remove radon at room temperature under detector-representative conditions, using a 97:3 Ar/CH₄ mixture. A ²²²Rn decay-chain Monte Carlo, including pileup and readout dead time, is combined with a joint-likelihood and MCMC analysis to predict the radon activity expected without a trap and thereby quantify trap performance. At a common no-trap reference activity, the 90% confidence-level lower limits on the radon reduction factor are 4.0 × 10³ and 3.8 × 10³ for the two Ag-ETS-10 campaigns, compared with 5.4 for activated charcoal under the same room-temperature conditions. The corresponding adsorption constants, expressed as K-factors, are 5.61 × 10³ and 5.32 × 10³ m³ kg⁻¹ for Ag-ETS-10 and 6.17 m³ kg⁻¹ for activated charcoal. The charcoal value is consistent with published room temperature values of approximately 3–10 m³ kg⁻¹, and the Ag-ETS-10 values lie within the range of previously reported room temperature silver-zeolite measurements in nitrogen, air, and argon. Our measurements provide the first validation of Ag-ETS-10 in which the radon activity is measured in situ by an operating dark matter detector, a spherical proportional counter filled with its own Ar/CH₄ target gas, establishing silver zeolite as a practical room temperature radon mitigation solution for gaseous rare event detectors.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Deng, Yuqi
Advisor dc:contributor.advisor
  • Marie-Cécile Piro, Department of Physics

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/85736

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Deng, Yuqi. Detector Response Simulation and Radon Trap Characterization for the NEWS-G Experiments. Doctoral thesis, University of Alberta, 2026. https://doi.org/10.7939/85736