Cyber-Physical Anomaly Monitoring and Mitigation in Power Distribution Systems

Abstract

dc:description.abstract

Power distribution systems represent the final stage of the electric grid, delivering electricity to end users at safe and desired voltage levels. In many regions around the world, core distribution system infrastructure, such as underground cables, was constructed decades ago and is now nearing or exceeding its expected lifespan. As a result, maintenance costs are rising, and the risk of equipment malfunction continues to grow, potentially leading to catastrophic failures. Meanwhile, with the growing demand for renewable energy, an increasing number of distributed energy resources (DERs) equipped with communication and control capabilities are being integrated into the power distribution systems, introducing new vulnerabilities to attacks on communication links. Consequently, cyber–physical anomalies, including both disturbances and attacks, have become a critical focus in industry and academia. In this thesis, we investigate monitoring and mitigation approaches to address cyber-physical anomalies in power distribution systems. Four main research topics are studies. Firstly, root cause classification for power disturbances is investigated, including incipient faults, constant impedance faults, capacitor switching events, and load switching events. Specifically, disturbance models are derived by exploiting their corresponding mathematical formulations or physical characteristics. Then, an estimator is developed for each disturbance model to estimate the unknown disturbance parameters based on the measurement data. Based on the estimation results, a hypothesis-testing-based classification scheme is proposed to identify the root cause by selecting the disturbance model that best fits the measurement data. Case studies based on the IEEE 13-Bus Test Feeder demonstrate that the proposed scheme not only classifies disturbances with a high accuracy rate but also provides insight into disturbance features through the estimation results. After a disturbance is identified as a fault, it is necessary to locate the fault to enable timely maintenance. In the second research work, a fault location scheme based on synchronous waveform measurements is investigated. A fault voltage model is derived through successive calculations using waveform measurements at the substation and branch ends. Based on this model, an estimator is designed to determine the fault distance along each line segment, incorporating a whitening process and a zero-padding technique to improve accuracy. The fault location is then pinpointed using these estimation results. Compared with existing schemes, the proposed scheme provides more accurate fault location results. Beyond power disturbances, securing the communication layer of the distribution system is equally important. In the third research work, an autonomous scheme is developed for the identification and mitigation of man-in-the-middle attacks. A trajectory-based method is designed to identify compromised control signals utilizing the local measurements at each DER. An estimator is then implemented to determine the frequency and amplitude components of the attack. The attack signals are subsequently reconstructed, and their adverse effects are mitigated by injecting the inverse of the reconstructed signals back into the system. The performance is evaluated under various attack signals to demonstrate the effectiveness of attack impact suppression. A more severe scenario arises when the communication link is not only compromised but completely lost, which is addressed in the fourth research work. In this work, a LoRa (Long Range)-based wireless backup strategy is developed to enhance system resilience against wired communication failures. Specifically, a LoRa-based wireless communication is utilized to transmit secondary control signals during wired communication outages, thereby maintaining desired frequency and voltage levels. A control parameter tuning mechanism is developed to adjust the PI controller parameters based on communication delay, transmission interval, and packet loss conditions to achieve optimal performance. The control performance is validated through real-time experiments using Universal Software Radio Peripheral (USRP) and OPAL-RT.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Communications
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Xiao
Advisors dc:contributor.advisor
  • Jing, Yindi (Electrical and Computer Engineering)
  • Liang, Hao (Electrical and Computer Engineering)

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/85843

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Zhang, Xiao. Cyber-Physical Anomaly Monitoring and Mitigation in Power Distribution Systems. Doctoral thesis, University of Alberta, 2026. https://doi.org/10.7939/85843