Back to search

University of Alberta

Automatic Ultrasound Pediatric Wrist and Elbow Fracture and Bone Assessment Using AI Methods

Abstract

dc:description.abstract

Wrist and elbow fractures are common pediatric injuries requiring rapid and accurate diagnosis in emergency settings. However, the current diagnostic care pathway in pediatric emergency departments involves long wait times for X-ray examinations and subsequent radiologist interpretation. Importantly, a substantial proportion of patients presenting to the emergency department do not ultimately have fractures. Ultrasound provides a radiation-free and accessible imaging alternative; however, its inherent noise and strong operator dependency make reliable interpretation challenging. This motivates the hypothesis that point-of-care ultrasound, combined with Artificial Intelligence (AI)-based analysis, could serve as an accessible clinical triage tool to rapidly identify non-fracture cases and prioritize patients with suspected fractures for further evaluation, with future potential for deployment in community settings to enable point-of-care triage, potentially reducing unnecessary emergency department visits and alleviating the burden on emergency care systems. Despite this potential, the development of such AI systems is hindered by several practical challenges, most notably the high cost of expert annotation and limited availability of clinical experts, resulting in sparse or incomplete labeled datasets. Motivated by these constraints, this thesis develops and evaluates AI methods for wrist and elbow ultrasound fracture detection and bony region segmentation, with particular emphasis on limited annotation, sparse supervision, and cross-domain generalization, using our dataset collected in 2021–2026 at the Stollery Children's Hospital and the cast clinic. First, we systematically evaluate the feasibility of AI-based fracture detection using classification and segmentation frameworks on wrist and elbow ultrasound datasets under fully supervised settings. The results demonstrate strong performance when dense annotations are available, confirming the effectiveness of AI models in this task. Second, to mitigate the reliance on expensive and scarce annotations, we propose annotation-efficient learning strategies, including a self-supervised learning framework and a visual in-context learning framework. These methods enable effective learning under limited annotation budgets and consistently improve performance across different model architectures and data regimes. Third, because ultrasound scans in the field are performed with a variety of equipment and users, we address the challenge of cross-domain deployment, where models trained on a fully annotated source domain must generalize to a target domain with significant domain shift and no annotations. A self-supervised learning-based strategy is proposed to improve robustness under this setting, enabling effective adaptation across domains. This could facilitate broader clinical adoption. Overall, this thesis demonstrates that effective AI systems for point-of-care ultrasound fracture detection can be developed on our collected dataset. With fully labeled data, the system achieves high diagnostic accuracy, yielding a sensitivity/specificity of 88.9%/90.9% for the wrist and 100%/71.4% for the elbow. Even under realistic clinical constraints, using a mere 5% of annotated data maintains robust bone segmentation with Dice Similarity Coefficients of 0.852 and 0.689 for wrist and elbow images respectively. Crucially, in the presence of probe-induced domain shifts on a completely unannotated novel dataset, the model still delivers a wrist bone segmentation Dice Similarity Coefficient of 0.722. The proposed methods provide unified frameworks for annotation-efficient learning and cross-domain robustness, making scalable and clinically deployable AI-assisted ultrasound triage systems feasible in pediatric musculoskeletal imaging.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhou, Yuyue
Advisors dc:contributor.advisor
  • Jaremko, Jacob L. (Medical Sciences-Radiology and Diagnostic Imaging)
  • Hareendranathan, Abhilash (Medical Sciences-Radiology and Diagnostic Imaging)

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/85863

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Zhou, Yuyue. Automatic Ultrasound Pediatric Wrist and Elbow Fracture and Bone Assessment Using AI Methods. Doctoral thesis, University of Alberta, 2026. https://doi.org/10.7939/85863