Abstract
dc:description.abstractBackground: Neuromuscular electrical stimulation (NMES) involves delivering current through electrodes placed on the skin over nerves or muscles. NMES-evoked contractions are primarily generated by activating motor axons directly, but part of the contraction is also generated by the activation of sensory axons which send signals through the spinal cord, synapsing onto motor axons through a reflex pathway. Each pathway generates a distinct electromyographic response: a motor M-wave and an H-reflex (i.e., Hoffmann’s reflex). NMES has enabled people to row and cycle following spinal cord injury (SCI), but its widespread application remains limited due to rapid contraction fatigability arising from non-physiological motor unit recruitment. Transcutaneous spinal cord stimulation (tSCS) is another technique being explored in neurorehabilitation, which involves passing current through electrodes placed on the skin of the back to target the spinal cord non-invasively. In individuals with SCI, tSCS has been shown to “boost” weak voluntary signals from the brain, modify spinal excitability, and amplify voluntary contractions. Its use to amplify NMES-evoked contractions, however, has yet to be extensively tested and as such, the goal of this proof-of-concept study was to examine the effect of combining tSCS with NMES (tSCS + NMES) on contraction amplitude and spinal excitability in neurologically intact participants. Hypotheses: We predicted that: 1) tSCS + NMES would generate larger contractions than NMES alone; 2) tSCS + NMES would produce larger H-reflexes than NMES alone while M-waves were unaffected; and 3) the effect of tSCS on contraction amplitude and H-reflex amplitude would increase as tSCS intensity and frequency increased. Methods: Twelve adult participants (21-62yrs, 6 males, 6 females) with no history of neuromuscular injury or disease were seated in a Biodex chair to measure isometric plantarflexion contraction amplitude of the right ankle. M-waves and H-reflexes were also recorded from the soleus muscle using electromyography. NMES was delivered to the tibial nerve as 0.2 Hz “single” pulses and at 20 Hz, both alone and paired with three intensities (0.6x-, 0.8x, and 1.0x-spinal-evoked response (SER) threshold) and two frequencies (30 and 100 Hz) of tSCS. Contraction amplitude was analyzed during sets of five 20 Hz NMES contractions (7s “on” 10s “off”), which ranged from ~5-70% of the individual’s maximum voluntary contraction amplitude. M-wave and H-reflex amplitudes were analyzed both during single NMES pulses and during the sustained contractions. All outcome measures were compared between NMES alone and tSCS + NMES trials. Multilevel hierarchical modeling was used for statistical analyses. Results: The addition of tSCS to NMES-evoked contractions resulted in small increases in contraction amplitude (1-2 %MVC) when applied at the high intensity (1.0x-SER threshold) compared to NMES only controls. H-reflexes were suppressed by tSCS during the 0.2 Hz “single” NMES pulses (~5-16 %Mmax) as well as the 20 Hz contractions (~1-2 %Mmax). This H-reflex suppression was more prominent during the single pulses, likely due to the absence of any rate-dependent depression, and became more suppressed at higher intensities and frequencies of tSCS. Discussion: These results suggest that tSCS may have dual effects on spinal structures. If tSCS increases presynaptic inhibition of afferents while simultaneously increasing motor neuron excitability, contraction amplitude could increase while H-reflexes are suppressed. Future studies should aim to confirm the mechanisms underlying our results. Should these results be reproduced, they would suggest that tSCS has the potential to be used during NMES-assisted rehabilitation protocols (such as NMES-cycling) to facilitate motor output while simultaneously decreasing spasticity, facilitating the ease of movement execution. This work, alongside future studies, advances our understanding of how electrical stimulation can modulate nervous system excitability, either enhancing or inhibiting output depending on which structures are activated and how they interact within the spinal cord.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- McConnell, Jocelyn C
- Advisors dc:contributor.advisor
-
- Collins, David (Kinesiology, Sport, and Recreation)
- Mushahwar, Vivian (Medicine/Neuroscience)
Subjects
dc:subject × 13Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/85907