University of Alberta
Artificial Intelligence-Assisted Musculoskeletal Ultrasound Analysis for Pediatric Upper Extremity Fracture Assessment
Abstract
dc:description.abstractPediatric upper-extremity fractures are common emergency-department injuries and frequently involve the wrist, forearm, and elbow. Radiography remains the standard first-line imaging method for confirming fractures, assessing displacement, and guiding treatment. However, many children with suspected injuries undergo radiography without ultimately having a fracture, motivating complementary triage approaches that may reduce unnecessary imaging in selected low-risk cases. Point-of-care ultrasound (POCUS) is portable, dynamic, and radiation-free, but its interpretation is operator-dependent and complicated by variable image quality and the large number of frames contained in ultrasound cine sweeps. This thesis developed and evaluated artificial-intelligence methods for extracting clinically meaningful information from pediatric musculoskeletal ultrasound and translating it into fracture-screening decision support.The thesis investigated two connected anatomical settings. In the wrist, Contrast-Limited Adaptive Histogram Equalization (CLAHE), automated bony-structure segmentation, and downstream fracture classification were evaluated. Raw and CLAHE-enhanced images both achieved a mean segmentation Dice score of 0.87 on the test set, showing that increased local contrast did not materially improve segmentation in the primary dataset. Predicted bony-structure masks nevertheless retained fracture-related information: combining ultrasound images with predicted masks achieved a frame-level ROC AUC of 0.97, while direct image-only classification achieved the highest subject-level performance. Qualitative Grad-CAM analysis further showed that segmentation-assisted classifiers could produce more anatomically localized activation around expert-annotated fracture regions. The elbow studies addressed a more indirect fracture-assessment problem by evaluating ultrasound-visible effusion as an imaging marker for fracture rule-out. Expert-annotated effusion was present in all fracture-positive subjects in the paired cohort, while its presence was also common among fracture-negative subjects, supporting effusion absence as a potential rule-out marker but confirming that effusion presence was not fracture-specific. Fracture-positive subjects also showed greater quantitative effusion extent. Automated effusion segmentation was subsequently developed for 2D POCUS cine frames. The selected binary volar ResNet34 U-Net achieved a test Dice score of 0.78 ± 0.05 and detection specificity of 0.94 ± 0.04, providing predicted effusion measurements for downstream subject-level analysis. Predicted effusion was then propagated from frame-level segmentation to subject-level fracture screening. An interpretable two-feature logistic-regression model combined the maximum predicted effusion area fraction with repeated high-effusion evidence across the cine examination and achieved test sensitivity of 0.92 ± 0.14, negative predictive value of 0.98 ± 0.04, and specificity of 0.76 ± 0.30. A complementary multiple-instance learning approach used segmentation-guided frame selection to classify selected ultrasound images directly and produced no pooled false-negative classifications in its volar-evaluable test cohort. Finally, reinforcement learning was investigated for sequential keyframe selection. Among the RL approaches, segmentation-guided nonvisual RL achieved the highest mean ROC AUC, but none of the evaluated RL pipelines outperformed deterministic selection of frames with the largest predicted effusion, which achieved a mean ROC AUC of 0.91 ± 0.08 with pooled sensitivity and negative predictive value of 1.00. Together, these studies support a staged AI-assisted POCUS framework in which clinically meaningful ultrasound information is identified, quantified, and aggregated for subject-level screening. The findings demonstrate the value of interpretable intermediate representations while showing that greater model complexity did not consistently improve performance. The proposed methods remain research prototypes rather than replacements for radiography. Larger multi-center cohorts, stronger reference standards, temporal and multi-view modeling, uncertainty estimation, and prospective evaluation are needed for clinical translation.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ezzelarab, Maha
- Advisors dc:contributor.advisor
-
- Hareendranathan, Abhilash (Radiology and Diagnostic Imaging)
- Jaremko, Jacob (Radiology and Diagnostic Imaging)
Subjects
dc:subject × 12Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/85913