Abstract
dc:description.abstractSlender reinforced concrete block masonry walls with effective height-to-thickness (h⁄t) ratios greater than 30 are commonly used as loadbearing elements in single-storey commercial and industrial buildings, including warehouses, schools, gymnasiums, and similar structures. Load-bearing walls are frequently subjected to combined axial load and out-of-plane lateral pressure. In slender walls the design is influenced by second-order effects because lateral deflection under axial load produces additional bending moment. An accurate estimate of effective flexural stiffness (〖EI〗_eff ) is therefore required to calculate deflections, moment magnification, stability response, and total design moment. In current Canadian and American masonry standards CSA S304-24 and TMS 402-22 simplified expressions are provided for effective flexural stiffness. But the flexural stiffness provisions have been shown in previous experimental and analytical studies to be conservative and to not fully capture the combined effects of cracking, axial load, reinforcement, masonry strength, slenderness, and second-order effects. In this thesis, the effective flexural stiffness of slender reinforced concrete block masonry walls subjected to combined axial and out-of-plane loading is investigated. Experimental stiffness values were evaluated from available slender wall test programs using beam-column formulations and measured lateral deflections. The experimental results were compared with CSA S304-24 and TMS 402-22 predictions to assess the accuracy and conservatism of current stiffness provisions. A mechanics-based analytical model was then validated against experimental load-displacement responses and stiffness degradation plots. After validation, the model was used to generate an analytical database covering wall thickness, slenderness ratio, masonry compressive strength, reinforcement configuration, axial load level, eccentricity, and spacing condition. A total of 403,200 simulated wall configurations was generated in the analytical database. After response classification and filtering, 17,133 under-reinforced cases were retained for model development, including 8,885 fully grouted and 8,248 partially grouted walls. The filtered cases were used to evaluate the variables controlling effective flexural stiffness and to support the development of a design-oriented predictive expression. Variable screening was performed using normalized trend plots, correlation analysis, random forest feature importance, permutation importance, model-tree exploration, and multicollinearity assessment. These methodologies were used to identify mechanically meaningful predictors and to reduce the inclusion of redundant variables. Nonlinear least-squares regression was then used to calibrate candidate expressions for normalized effective flexural stiffness. The results indicate that effective flexural stiffness was generally underestimated by CSA S304-24 and TMS 402-22 for the wall cases considered with greater conservatism observed for CSA S304-24. The database trends show that effective stiffness is governed by the combined influence of cracked-section stiffness, axial load level, slenderness, reinforcement configuration, material stiffness, eccentricity, and moment demand rather than by a single parameter. A simplified representation of these mechanics-based trends was obtained through the proposed regression expression within the limits of the database. The study supports the development of refined stiffness expressions for slender reinforced masonry wall design and provides a basis for future reliability calibration and code-oriented evaluation.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Structural Engineering
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Marin Medina, Angie Dayanna
- Advisor dc:contributor.advisor
-
- Pettit, Clayton (Civil and Environmental Engineering), Cruz-Noguez, Carlos (Civil and Environmental Engineering)
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/85938