University of Alberta
Unsteady Modeling of Air Flow and Pollutant Transport in Sanitary Sewer Systems
Abstract
dc:description.abstractSewer airflow plays a critical role in odor problems because it transports gaseous hydrogen sulfide (H2S) within sewer systems and promotes its emission to the atmosphere through manhole openings. Variations in sewage flow can affect both in-sewer processes and airflow dynamics, which in turn influence H2S transport and emission. However, the coupled behavior of unsteady hydrodynamics, sewer ventilation and H2S transport remains insufficiently understood, mainly because suitable models capable of simultaneously representing these processes in both wastewater and sewer air are still lacking. Field measurements were conducted in a sewer system downstream of a pump station, and the measured air pressures were used to validate a three-dimensional (3D) computational fluid dynamics (CFD) model for exploring the mechanisms of transient sewer airflow. The results showed that pump startup generated sharp positive pressure spikes and caused air emission through manhole openings, with peak pressures attenuating at downstream manholes. The air pressure then rapidly dropped, accompanied by stable air induction at upstream manholes as airflow was driven downstream by water surface drag. After pump shutdown, negative pressure spikes occurred in all manholes. The effects of orifice size, pump discharge, and pipe length on air pressure and ventilation were numerically investigated, and analytical solutions were derived to estimate manhole air pressure spikes. To overcome the high computational cost of 3D CFD model for system-scale applications, a one-dimensional (1D) unsteady two-phase model was developed for sewer air and water flow using a decoupled strategy, in which the air and water phases were solved separately to accommodate their different timescales. The model accounts for pressure gradients, interfacial drag, and wall friction, allowing efficient simulation of transient airflow and manhole ventilation over a wide range of timescales. Key parameters were calibrated using the field-validated 3D CFD results. Application to an idealized sewer network with a main trunk and two laterals (10 pipes and 10 manholes) showed that the model successfully reproduced pressure variations and manhole ventilation induced by an upstream pumping event (144 L/s discharge and 3 min pump operation), with total emitted and induced air volumes of 1.8 m3 and 22.8 m3, respectively. Under periodic inflow conditions, a practical criterion for approximating unsteady airflow as steady was also proposed for the configurations examined in this study, indicating that the steady approximation is reasonable when the Strouhal number is below 0.05. Building on this airflow framework, a 1D unsteady H2S transport model was developed for sanitary sewer systems. The model incorporates advection, longitudinal dispersion, mass transfer, and air ventilation to simulate aqueous and gaseous H2S concentrations in pipes and manholes. It was applied to a published field case in the gravity sewer downstream of Pump Station Neukölln II in Berlin. Sensitivity analyses indicated that the inflow aqueous H2S concentration is the dominant factor controlling the overall magnitude of gaseous H2S concentrations, whereas manhole opening size mainly affects gaseous H2S peaks and post-shutdown decay through ventilation. Longitudinal dispersion smooths and redistributes concentration, with a more noticeable influence on the gaseous H2S when dispersion coefficient exceeds 0.01 m2/s. The hydraulic jump formed during pump operation can enhance local mass transfer and contribute to exceptionally high gaseous H2S peaks. After calibration, the model reproduced the major observed features, including the rise in aqueous H2S, the sharp gaseous H2S peaks during pumping, and the post-shutdown decay in both phases. The model was further applied to the Big Lake Sewer System in Edmonton, Alberta, Canada to evaluate its performance in a larger sewer network. The results showed that the model reasonably reproduced wastewater flow, air pressure variations, and the general spatial and temporal patterns of aqueous and gaseous H2S concentrations. Further improvements are excepted to enhance its predictive accuracy. Overall, this thesis advances the understanding of sewer air ventilation and H2S transport under unsteady sewage flow conditions and provides a unified 1D modelling framework that integrates a decoupled two-phase hydrodynamic model with a two-phase pollutant transport model to predict the spatiotemporal distributions of gaseous H2S concentrations in sanitary sewer systems. The proposed framework provides a useful modelling approach for improving the understanding of odor emission in sewer systems and supporting the future development of odor control strategies.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Water Resources Engineering
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wang, Chenxi
- Advisors dc:contributor.advisor
-
- David Z. Zhu, Civil and Environmental Engineering
- Peter M. Steffler, Civil and Environmental Engineering
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/86023