Back to search

University of Alberta

A Comparative Evaluation of Point-of-Care Measurement Technologies for Kinematic Assessment of Hand Function

Abstract

dc:description.abstract

“A Comparative Evaluation of Point-of-Care Measurement Technologies for Kinematic Assessment of Hand Function” evaluates the effectiveness, availability, and clinical feasibility of different point-of-care technologies and assessment technologies that can be used to enable remote hand assessments. This thesis studies the existing landscape of literature on these technologies and maps the existing evidence to uncover the gaps in the field. It also includes a distinct research project that evaluates and compares an array of different existing commercial technologies that could be used by clinicians to complete remote assessments of hand function in rural or remote communities. By utilizing both a scoping review and a cross-sectional within-subject experimental design, this thesis provides insight into the factors that may impact the effectiveness of technology in enabling assessment of different aspects of hand function. The combination of these two types of research provides a more comprehensive and detailed set of results that can be used to inform clinicians and the future research direction that is needed in this area of study. The scoping review synthesized data from 141 studies. Findings revealed a trend towards the use of computer-vision-based or markerless motion capture methods for the assessment of hand kinematics. Furthermore, many studies included in the review used a combination of different technologies for a comprehensive assessment of hand function. Additionally, the evidence revealed a gap between the point-of-care technology in the validation stage and the technology ready to be deployed in a clinical or remote environment. Results from the experimental comparison demonstrated that, while each of the three systems is not currently ready for clinical use in terms of absolute accuracy, the Manus system has the highest reliability when measuring joint angles (ICC up to 0.95). Specifically, the markerless systems demonstrated accuracy degradation during complex grasping tasks due to occlusion. However, each system has areas of poor performance, and none meet current clinical standards. Ultimately, while these technologies could potentially supplement clinical judgment or traditional methods of hand assessment, they do not yet meet the rigorous accuracy standards of manual finger goniometry. In synthesizing the results from both studies, this thesis provides a comprehensive overview of the current state of existing technologies that can assess hand kinematics. It also describes the accuracy and reliability of a subset of these commercially available technologies, i.e. data gloves and computer-vision hand tracking software, for clinical use. By providing clinicians with the information from the foundational pilot study, the path towards choosing the most appropriate technology to implement into a remote clinical workflow is set out, and the next step in further research is presented.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Rehabilitation Science
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hopkins, Jane E.
Advisor dc:contributor.advisor
  • Ferguson-Pell, Martin (Rehabilitation Medicine)

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/86138

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Hopkins, Jane E.. A Comparative Evaluation of Point-of-Care Measurement Technologies for Kinematic Assessment of Hand Function. Master's thesis, University of Alberta, 2026. https://doi.org/10.7939/86138