Abstract
dc:description.abstractMagnetic Resonance Imaging (MRI) is a versatile diagnostic modality, widely favoured for its ability to produce high-resolution images of soft tissue structures under various contrast mechanisms. However, widespread access to MRI remains limited, primarily due to the high financial investment necessary to procure the systems. In addition to the steep upfront cost, installation requires specialized infrastructure (MRI suites), while clinical operations require regular maintenance, staffing, and cryogenic refills, further increasing expenses. These costs create a barrier for smaller clinics in rural or underdeveloped settings, thereby restricting or delaying diagnosis for many patients worldwide. In an effort to improve accessibility, there has been growing academic and commercial interest in low-field, low-cost, and portable MRI for applications in resource-limited settings and point-of-care wards where patient transport is difficult. In parallel, radiofrequency (RF)-based spatial encoding has gained renewed attention, in which tailored RF fields (B1) replace traditional switching gradients of the main magnetic field (B0). This approach enables a cost-effective, low-complexity imaging system while providing additional benefits, such as silent imaging. One such method is transmit array spatial encoding (TRASE), which performs spatial encoding with linearly varying B1 field phases (i.e., B1 phase gradients). TRASE is particularly well-suited for low-field imaging and, when paired with a lightweight Halbach magnet, offers the potential for a simplified, low-cost, and portable MRI system. One challenge for TRASE, however, is the RF transmit array required to generate the phase-gradient fields, which is sensitive to even minor inter-element coupling. Although 2D TRASE imaging has been demonstrated, the complex transmit array produced a difficult-to-access imaging volume much smaller than the coil formers. To address this, in 2019, the twisted solenoid (TS) was introduced, which improved on earlier coil designs through its efficient cylindrical formers; however, the coils were long and required two elements for 1D encoding and a third for 2D imaging. This poses a challenge for 2D imaging, as decoupling three solenoidal coils is exceedingly difficult during the high-duty-cycle TRASE sequence. The goal of this project, therefore, is to simplify the TS transmit array to enable full 2D RF encoding without the need for B0 switching gradients, with potential clinical applications in mind. The TS coil formers improved compatibility with cylindrical Halbach magnets; however, the specific geometry created large conductor gaps on either end, resulting in long coils with relatively short imaging volumes. Although this design is adequate for extremity imaging, it becomes challenging for more restrictive anatomies, such as the head or cervical spine. I therefore designed a length-truncated TS and demonstrated it on an inhomogeneous Halbach magnet. Simulated and experimental results indicate that the truncated variant maintains a similar imaging volume to the untruncated version whilst significantly reducing the coil length by as much as half. While 1D TRASE encoding with two isolated coils has been demonstrated previously, 2D imaging via Cartesian sampling with three coils (Cartesian TRASE) requires impractical inter-element isolations of at least –30 dB. To simplify this strict isolation requirement, I introduced a 2D radial encoding scheme (Radial TRASE) using the proven two-coil 1D TRASE transmit array. This method is enabled by the TS coil, which changes its 1D encoding direction when rotated axially, allowing a full projection-based acquisition. For the first time, 2D TRASE MR images with minimal distortion were demonstrated using the TS coil without B0-switching gradients. Although Radial TRASE involves fewer RF coils within the transmit array, early experiments suggested an unexpected tolerance to residual coupling, even at isolations of –20 dB. Encouraged by these results, I wrote a Python-based Bloch-equation simulator to quantify the isolation requirements of Radial TRASE. At the same time, the trade-off between strong phase-gradient fields (related to spatial resolution) and B1 inhomogeneity was evaluated. The results of this simulation established design criteria for the TS coil geometry and demonstrated that Radial TRASE exhibits minimal artifacts for isolations of –16.5 dB or better. By reducing RF hardware requirements and simplifying the RF transmit array, Radial TRASE improves upon the feasibility of a low-cost system relative to prior Cartesian TRASE variants. In combination with a lightweight Halbach magnet, Radial TRASE offers a practical basis for a low-cost and portable MRI system suitable for applications where conventional scanners are not feasible.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Medical Physics
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sedlock, Christopher James
- Advisor dc:contributor.advisor
-
- Jonathan Sharp (Department of Oncology)
Subjects
dc:subject × 9Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/86150