University of Alberta
Reducing Precious Metals in Anion Exchange Membrane Water Electrolyzers: Performance and Loss Analysis
Abstract
dc:description.abstractHydrogen is recognized for its potential as a clean energy carrier that can be easily generated and stored [1]. Anion exchange membrane water electrolysis (AEMWE) is a hydrogen production technology capable of combining advantages of proton exchange membrane water electrolysis (PEMWE) and alkaline water electrolysis (AWE). AEMWE provides an alternative to PEMWE systems, dependent on expensive and scarce Platinum-Group Metals (PGMs) catalysts, by enabling significantly cheaper components (Ni, Co, and Fe). Concerns remain, however, regarding the activity and durability of these catalysts. Thus, authors have found different porous media materials that work as the electrode without a catalyst layer [2]. The first part of this thesis investigates the integration of three non-PGM anode electrodes in AEMWE, namely a nickel felt (NF), NiFe electrodeposited stainless steel mesh, and SS sinters, for the oxygen evolution reaction (OER). For the hydrogen evolution reaction (HER), a cathode catalyst layer of platinum on carbon (Pt/C) is fabricated by inkjet printing on top of an Aemion membrane (loading of 0.1 mg cm−2 Pt). Ex-situ characterization techniques were conducted, with particular attention to the anode morphological properties and the cathode catalyst ink parameters. Testing was conducted at 80 °C, 1 M KOH, and an electrolyte flow-rate of 4.5 mL min−1, where at 1 A cm−2 the three cells yielded: 1.876 V for the NF; 1.856 V for 3D-SS; and a best result of 1.83 V for NiFe-SS. The latter was selected for the main cell architecture, achieving repeatable results in four individual cells. Our work was then compared to similar systems reported in the literature under comparable operating conditions. The results observed varied due to differences in Pt loadings; therefore, a normalized metric was employed. This work achieved 1.68 V, with 600 A cm−2 / mg PGM, one of the highest performances per milligram of platinum. Three parametric studies were conducted to investigate the effects of temperature, electrolyte concentration, and feed method: two-electrode feed (TEF) and anode only feed (AOF). Results show an enhanced performance with temperature increase from 60 °C to 80 °C. Decreasing KOH concentration in the electrolyte from 1 M to 0.1 M KOH resulted in poorer performance, consistent with the literature [3]. It was concluded that Aemion+ membranes provide competitive performance (1.83–1.87 V at 1 A cm−2) when operating within a concentration range of 0.25–1.0 M KOH. At 0.1 M KOH, acceptable performance was achieved (1.98 V at 1 A cm−2). For the feed method effect, polarization curves for both AOF and TEF operation showed that AOF was comparable to TEF values at medium-to-high current densities, in accordance with previous works in this group [4]. Lower onset potentials were observed for AOF compared to TEF at 10 mA cm−2. These results suggest that AOF yields similar losses to TEF while using half the electrolyte volume without significant dry-out. To further investigate the origin of performance-limiting processes, the second part of this study aims to disentangle the individual voltage losses at the anode and cathode electrodes. A diagnostic tool is introduced through the development of a three-electrode setup for in-situ testing. The first implementation of multiple edge-type reference electrodes (REs) in AEMWE is explored. Inkjet printing is used to fabricate the reference electrodes directly on the membrane, and a novel bipolar plate design is developed with hydrogen supply, enabling a reversible hydrogen electrode (RHE). The multiple-RE approach served as a detection tool for misalignment effects which may introduce misleading potentials to either the anode or cathode measurements. Three REs were used to ensure that erroneous half-cell potentials were not present. Then, the anode and cathode losses were successfully recorded, yielding identical measurements at 1 A cm−2 with less than 15 mV drift between REs. At this operating current, the cathode losses showed −333 mV while the anode yielded 408 mV. Contrary to the common assumption that the anode dominates performance limitations, these findings demonstrate that cathode limitations are also a significant contribution to the overall cell losses. In summary, this thesis developed an AEMWE that achieved competitive performance without any PGM material at the anode and with reduced cathode Pt loadings. It offers insight into key limiting processes such as kinetic and ion transport losses under low-alkaline or anode-feed operation. The novel three-electrode diagnostic tool developed in this thesis shows that the cathode also contributes significantly to the overall cell potential losses and should not be neglected as in PEMWE systems. These findings highlight the opportunities for achieving reliable and affordable hydrogen production using AEMWE technology.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Quintero, Andrea I.
- Advisor dc:contributor.advisor
-
- Secanell, Marc (Mechanical Engineering)
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/86154