Decarbonizing the heating and cooling sector requires the integration of renewable energy sources. Solutions for this integration will not be found through the individual-building scale. This makes the problem not only a technological problem but also an infrastructure challenge. This is where district energy systems (DES) have recently gained considerable interest, as they provide the necessary infrastructure and flexibility. DES comprise a network of pipes connecting the buildings in a neighborhood, so that they can be served from a centralized plant. This approach allows the use of any available local renewable sources. District heating and cooling systems have evolved through multiple generations, each introducing new operating conditions, heat carriers, and energy conversion technologies. The most important factor in this generational development was the operating temperature, which has progressively decreased from one generation to another, from approximately 200 °C in the first generation to near-ambient temperatures in the most recent generations, also known as Ambient Temperature District Heating and Cooling (ATDHC) systems. The integration of geo-exchange technology with DES has been made technically feasible in these low-temperature generations due to their low operating temperature levels where reversible booster heat pumps at the buildings are used to provide heating and cooling demands. At the central plant a ground-source heat pump (GSHP), also known as geothermal heat pump, exchanges heat with the ground through a ground heat exchanger known as a borefield (BHF). Despite the environmental benefits of these systems, the widespread adoption of this technology remains limited by its high upfront cost, which is largely associated with borefield size. The borefield size is affected by the ground conditions, loads of the buildings, and a variable parameter which is the operating temperature of the system. This requires an optimization study to examine the effect of the operating temperature and the location on the borefield size to define optimal operating conditions. This paper-based thesis has three main objectives, each addressed in one chapter and published in a peer-reviewed journal. The first objective is to examine, categorize and compare the technical details of previous DES optimization studies in the literature, and to identify the most common methodologies and application. The literature review shows that previous optimization studies on DES traditionally employ mathematical optimization and focus on energy balances between supply and demand and use simplified temperature dependencies formulations. Including these temperature dependencies in the optimization analysis is essential for low-temperature DES. Compared with mathematical optimization, simulation-based optimization (i.e., parametric) provides a more accurate representation of the complex thermal interactions within the system. The second objective is to develop the modeling framework needed for the analysis. The modeling framework is developed using OpenModelica which is an equation-based object-oriented language used for the modelling and simulation of multi-domain physical systems. The model is coupled with an iterative, dynamic, long-term borefield (BHF) sizing approach. The model is verified against a reference case study, and then applied to Canadian case studies to evaluate system performance. The third and the main objective of the thesis is to conduct a long-term (i.e., 20 years) simulation based optimization study to investigate the effect of operating temperature in a geo-exchange district heating and cooling system, with the aim of minimizing borefield size and examining the heat pump electricity consumption. The optimization study is conducted for a residential type of buildings in three different cities in Canada representing three different climate zones and therefore different weather and ground conditions. The three cities are Toronto (Climate zone 5A), Edmonton (Climate zone 7), and Vancouver (Climate zone 4C). The results show that the relationship between operating temperature and borefield size is nonlinear and governed by the building load profile, undisturbed ground temperature, and entering liquid temperature (ELT) design limits. The operating temperatures, reported as (heating, cooling), that achieve the minimum borefield size are found to be (10, 10) °C for Toronto, (25, 10) °C for Edmonton, and (40, 10) °C for Vancouver. The central ground-source and the booster heat pumps at the district level exhibit opposing electricity-consumption trends. Over 20 years of operation, lower operating temperatures are found to reduce the total system electricity consumption.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Abdelghani, Diaa, MM
Advisor dc:contributor.advisor
  • Seama Koohi (Mechanical Engineering)

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/86195

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Abdelghani, Diaa, MM. Optimization of Geo-Exchange District Heating and Cooling Systems. Master's thesis, University of Alberta, 2026. https://doi.org/10.7939/86195