University of Alberta
A customized physical model of device-patient interactions for nasal masks
Abstract
dc:description.abstractObstructive sleep apnea (OSA) is a prevalent breathing disorder characterized by intermittent airway obstruction disrupting oxygen levels and sleep. Continuous positive airway pressure (CPAP) is the gold standard treatment for OSA requiring well-fitting non-invasive ventilation (NIV) masks. Custom NIV masks aim to provide well-fitting masks for individuals experiencing poor fit with commercial options. In vitro testing of NIV masks is limited due to a lack of individualized benchtop models analyzing leak, especially for custom masks. This thesis discusses the development and use of an easy to produce individualized testing apparatus that captures device-patient interactions through a silicone soft tissue model for in vitro nasal mask leak testing. The iterative process of improving apparatus design and manufacturing methods is presented to communicate design intent and help guide future models. The finalized process used accessible software, tools, and materials to allow for easy production of future apparatus. 3D facial scans were used to produce the individualized testing apparatus used herein for material selection. Mask leak testing was done for one individual in vivo and in vitro at different CPAP pressures and mask tightness for a custom and a commercial NIV mask to evaluate silicone materials used to model facial soft tissue. Young’s modulus and silicone layer thickness were adjusted to obtain in vitro air leak rates similar to measured in vivo results. Young’s modulus of the soft tissue model was found to be more significant than silicone layer thickness when simulating mask leak. The silicone model with a modulus of 92.1 kPa and a uniform 12 mm layer, paired with a 350 g mask loading protocol produced the closest correlation between in vitro and in vivo data. In vivo leak trends between the different masks and CPAP pressures were reproducible using this material selection. The custom mask was found to produce higher unintended leak than the commercial mask for the study participant at both tested CPAP pressures. The silicone model was further used to demonstrate novel mask testing methodology that calculates air pressure at the nostrils throughout the breathing cycle with data output from a lung simulator. Increased mask leak resulted in decreased nostril pressure, with losses proportional to the set CPAP pressure. Testing of different breathing profiles with constant breathing rates and increasing tidal volumes identified that increased inhalation flowrates resulted in greater pressure deficits at the airway entry. Cumulative pressure loss effects were expected when combining higher mask leak with increased tidal volumes, but clinical relevance is uncertain. The developed manikin and testing methodology provide novel, feasible, individualized, and quantitative testing methodology for NIV masks.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Graf-Alexiou, Lucas
- Advisor dc:contributor.advisor
-
- Martin, Andrew R. (Mechanical Engineering)
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/86209