Abstract
dc:description.abstractUltrahigh field MRI which utilizes MRI scanners with main magnetic fields of > 7T are rising in popularity due to their increased signal to noise ratio and high-resolution imaging capabilities. These advantages allow for small lesions that are difficult to see with lower field strengths to be more easily detected, and for fine brain structures to be studied in vivo. However, the increased field strength results in a shortened RF wavelength, which in turn results in more prominent RF wave interference within anatomy such as the human head. This interference causes RF field inhomogeneity, manifesting as increased tissue heating, inconsistent contrast, and magnetic field nulls which appear as voids in the reconstructed image. In addition, traditional quadrature volume coil designs (birdcage, TEM coils), which are common for lower field strengths, become highly sensitive to patient loading at ultrahigh fields. Parallel transmit arrays and B1 shimming are effective at countering the field inhomogeneities, but are time consuming to construct, require additional computational resources, and are more difficult to use. Furthermore, some applications like quality assurance do not require the full flexibility of parallel transmit and thus could take advantage of the simplicity of a quadrature volume coil. Metasurfaces are periodic arrays of subwavelength unit cells with a planar structure built using conductors and dielectrics. In this work metasurface technology is applied to ultrahigh field RF coil design to create a quadrature volume head coil for 10.5T MRI (Larmor frequency of 447 MHz). A metasurface liner was designed using simulations that supported the propagation of a mode with a magnetic field suitable for MRI below the natural cutoff frequency of its RF shield. Ports were connected to the liner at two orthogonal locations which permitted quadrature drive like a birdcage coil. The metasurface liner was printed onto four flexible printed circuit boards and assembled by soldering them together then wrapping the sheet around a 3D printed former. Small tuning adjustments were made using four trimmer capacitors placed symmetrically around the nondriven end of the coil. The liner is surrounded by an aluminum RF shield, and matching circuits are attached to two locations separated by 90° to provide feed ports. The measured transmit efficiencies and simulated safety efficiencies for the metasurface coil and the pTx array used for comparison indicate that, while the metasurface coil has lower transmit efficiency, more power can potentially be supplied to it without exceeding tissue heating constraints. Loading the metasurface coil with a head-shaped phantom caused a tuning shift of only ~0.2 MHz, which is much less sensitive than other quadrature volume coils. This work demonstrates that a head-sized quadrature volume coil can be built for 10.5T UHF MRI with performance comparable to that of a pTx array. Potential improvements to the coil were also investigated through simulations including suppressing surface modes and adding detuning capability for use with a separate receive array. Driving the coil with a waveguide mode was found to be the most effective method to suppress the surface wave, though implementing this strategy would require using an antenna. Further simulations are required to assess the feasibility of this approach, including designing a suitable antenna that does not block access to the bore. For detuning, RF traps were tested. The coil rejected an incident waveguide mode when the RF traps were in the blocking mode, indicating that the coil was successfully detuned. However, this does not prove that the metasurface coil would be decoupled from a receive array inserted into it. A more detailed simulation is required to assess the degree of detuning this method provides but is nonetheless promising.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Medical Physics
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rémillard, Léo, J.É.
- Advisor dc:contributor.advisor
-
- De Zanche, Nicola (Oncology)
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/86224