Back to search

University of Alberta

Evaluation of Impact of Energy Sharing on Bidirectional Low-Temperature District Energy Systems in Vancouver

Abstract

dc:description.abstract

Fifth-generation district heating and cooling (5GDHC) systems have emerged as a promising approach for reducing energy consumption and greenhouse gas emissions in Canadian communities. These systems operate using low-temperature bidirectional networks that enable simultaneous heating and cooling, direct thermal energy exchange between buildings, and the integration of renewable and waste heat resources. Their performance depends largely on the ability to balance thermal demands within the district and maximize energy sharing among connected buildings. However, there remains limited understanding of how building demand composition influences energy-sharing potential and system operation, including total energy consumption and central plant capacity requirements. This thesis first reviews existing approaches for modelling building thermal demands and evaluating energy-sharing potential in district energy systems, with a particular focus on fifth-generation district heating and cooling networks. Building on the identified research needs, representative hourly heating and cooling demand profiles for residential, commercial, office, and healthcare buildings were generated using eQUEST 3.65 based on assumptions derived from the U.S. Department of Energy prototype building models. These demand profiles were then used as inputs to a dynamic simulation model of a bidirectional low-temperature district energy system developed in OpenModelica. The integrated modelling framework was used to investigate the relationship between building demand composition, energy sharing, and system performance. The framework is intended as an exploratory sandbox model rather than a calibrated representation of a specific operating district energy system; therefore, its numerical results should be interpreted only to assess the ability of the developed modelling approach to capture variations in system performance across the investigated scenarios. To quantify energy-sharing potential, district demand overlap coefficient (DOC) is used to represent the theoretical opportunity for energy sharing based on building demand profiles, while a network DOC is used to evaluate the actual energy sharing achieved during system operation. To assess the robustness of the system-level comparisons, the model behaviour was compared with a published 5GDHC reference case and interpreted as a system-level benchmark rather than full validation of a specific district. A local sensitivity analysis was then conducted for five key demand, heat-pump, and operating parameters, together with a coupled analysis of the network temperature limits. These analyses were used to determine whether the main conclusions remained consistent under changes in modelling assumptions and numerical settings. The results show that building demand composition is a key factor influencing energy-sharing performance. Within the investigated scenarios, district configurations with higher demand overlap achieved up to 11.5% lower annual electricity consumption and a 24% reduction in central plant capacity compared with districts dominated by a single building type, demonstrating the importance of considering thermal demand diversity during system planning and design. These values are specific to the investigated scenarios and are used to illustrate the ability of the modelling framework to capture variations in system performance as building demand composition changes. Sensitivity analyses further highlight the influence of network operating conditions and central plant performance assumption on the balance between energy sharing and heat pump performance. Overall, the findings indicate that improving the compatibility and temporal overlap of building heating and cooling demands can reduce central plant dependence and capacity requirements within the investigated modelling framework. The study also demonstrates how an integrated eQUEST-OpenModelica workflow can be used to explore the influence of building demand composition on low-temperature district energy system performance. These results provide insights into the design and operation of future low-temperature district energy systems in Canada.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Grantor
University of Alberta
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Naseryar, Fatemeh
Advisor dc:contributor.advisor
  • Koohi, Seama (Mechanical Engineering)

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/86312

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Naseryar, Fatemeh. Evaluation of Impact of Energy Sharing on Bidirectional Low-Temperature District Energy Systems in Vancouver. Master's thesis, University of Alberta, 2026. https://doi.org/10.7939/86312