Back to search

University of Alberta

Online measurement and monitoring of power system impedance and load model parameters

Abstract

dc:description.abstract

In power system studies, some parameters cannot be measured directly by using the currently existing power meters. These power system parameters include the power system Thevenin impedance, harmonic impedances, zero sequence impedance, and the load model parameters. The power system’s Thevenin impedance at a load bus is an important parameter for power system planning and operation. The effects of changing the system operation conditions on voltages at the load buses can be easily determined if the power system impedance parameters are known. Moreover, by knowing the Thevenin equivalent parameters, one can calculate the system’s voltage stability margin and maximum loadability. The knowledge of power system harmonic impedances is necessary for harmonic mitigation, determination of harmonic limit compliance, prediction of system resonance, and harmonic propagation studies. Moreover, real-time monitoring of the system’s harmonic impedances provides significant improvements to the design and operation of active filters. The system’s zero sequence impedance at the substation bus is also important information for power system studies. It is used to calculate the different ground fault levels at substations. Furthermore, the loads in power systems play a significant role in power system planning, control, and stability analysis. Having reliable and accurate models of the loads is essential for designing automatic control systems and optimizing their configuration. Obtaining such models has been a challenging problem for power system engineers for decades, especially in the current deregulated market environment. This thesis presents newly developed and verified algorithms for online measurement and monitoring of these power system parameters. The algorithm proposed for monitoring the system’s Thevenin, harmonic, and zero sequence impedance parameters, uses the natural variations of the loads connected to the substations. The proposed algorithm for monitoring of load model parameters uses the voltage and current waveforms captured during the operation of the Under Load Tap Change (ULTC) transformers installed in the distribution substations. The proposed algorithms are applied to several field measurements from different substations. The results show that the algorithms fulfill the requirements for the online measurement and monitoring of power system Thevenin, harmonic and zero sequence impedances as well as the load model parameters.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • AREFIFAR, SEYED ALI
Advisor dc:contributor.advisor
  • Wilsun Xu (Electrical and Computer Engineering)

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R3WM51

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

AREFIFAR, SEYED ALI. Online measurement and monitoring of power system impedance and load model parameters. Doctoral thesis, University of Alberta, 2010. https://doi.org/10.7939/R3WM51