Back to search

University of Alberta

Do Wearable Fitness Devices Correlate With Performance-Based Tests of Work-Related Functional Capacity

Abstract

dc:description.abstract

The purposes of this study were to: (1) Determine the magnitude and direction of correlation between participant performance on five exercises taken from a Functional Capacity Evaluation (FCE) and scores from Actigraph activity monitors; and (2) Compare the results of two different placements of Actigraph devices. We used a cross-sectional design and convenience sampling to collect data from 46 healthy participants. Each participant completed five exercises while equipped with two Actigraph devices, one worn on the dominant side waist and one on the non-dominant wrist. The exercises included were 5-repetition maximum lifting (floor-to-waist, overhead and front carry), a sustained overhead work endurance task, and the 6-minute walk test. Analysis included calculating Pearson regression coefficients between maximum exercise performance and Actigraph vector magnitudes along with Intraclass Correlation Coefficients to compare the two Actigraph placements. Forty (86.9%) participants had complete data and were included in analysis. Participants were predominantly young (x=23.73), male (54.30%). Findings indicate Actigraph vector magnitude data from the device worn on the waist correlated positively (r =0.39-0.64, p <0.001 to 0.08) with maximum lift performance and the 6-minute walk test distance (r =0.66, p <0.001). Actigraph data from wrist placement was not significantly correlated with FCE items except when comparing average vector magnitude data and waist to crown lift (r =0.44, p <0.001). There was no significant correlation in either Actigraph placement for vector magnitudes and overhead work time. Intraclass correlation coefficients between the two Actigraph placements ranged from poor to acceptable agreement (ICC =0.24-0.70, p < 0.001 to 0.19). We conclude that Actigraph device output correlated moderately with maximum performance on FCE lift and ambulation tests. Waist placement appears more suitable than wrist during performance-based tests. Actigraph devices may be useful during FCE evaluations and add another quantitative indicator of performance.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Rehabilitation Science
Grantor
University of Alberta
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Karpman, Jesse
Advisor dc:contributor.advisor
  • Gross, Doug (Physical Therapy)

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R34T6FF96

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Karpman, Jesse. Do Wearable Fitness Devices Correlate With Performance-Based Tests of Work-Related Functional Capacity. Master's thesis, University of Alberta, 2017. https://doi.org/10.7939/R34T6FF96