Back to search

University of Alberta

Improving Clinical and Experimental Normothermic Ex situ Liver Perfusion For Future Application

Abstract

dc:description.abstract

The past decade seen an increasing interest in ex situ normothermic liver machine perfusion as a promising alternative preservation strategy for potential expansion of the donor pool. Herein, my intent is to place my own contributions to this field within the greater context of ex situ liver perfusion, and trust that the reader may appreciate how these may further potentially advance our appreciation of how NMP technology may be more optimally applied to graft preservation and assessment. The two experimental ex situ NMP studies that we published previously addressed basic but important questions concerning NMP circuit priming, and the validity of ‘on circuit’ transaminase measurement for viability assessment. Before these studies, the kinetics of transaminase production, degradation and clearance within a closed ex situ circuit were not known. Our first published clinical NMP series was the first time that this technology was applied in North America. That study demonstrated that NMP technology was safe and feasible in a Canadian setting, and addressed the unique potential of ex situ perfusion to disrupt established transplant practice within the context of a geographically vast land. The second published clinical series (Bral shared first authorship), is the first published study to demonstrate both ongoing utility and increased practicality with a ‘back-to-base’ implementation strategy that avoids a need to transport heavy and complex machinery between the donor and recipient centres. Looking towards the next iterative steps in application of NMP technologies, we applied an in vivo murine ischemia reperfusion model as a screening tool to assess the efficacy of selected therapeutics, with the intention of prescreening these compounds for future translational application into an experimental ex situ II liver circuit. Most of these publications have been cited in the discourse surrounding NMP, and we trust have formed part of the foundation on which the technology will move into the future.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Experimental Surgery
Grantor
University of Alberta
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bral, Mariusz
Advisor dc:contributor.advisor
  • Shapiro, James (Department of Surgery)

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Permission is hereby granted to the University of Alberta Libraries to reproduce single copies of this thesis and to lend or sell such copies for private, scholarly or scientific research purposes only. Where the thesis is converted to, or otherwise made available in digital form, the University of Alberta will advise potential users of the thesis of these terms. The author reserves all other publication and other rights in association with the copyright in the thesis and, except as herein before provided, neither the thesis nor any substantial portion thereof may be printed or otherwise reproduced in any material form whatsoever without the author's prior written permission.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/r3-75yw-ez62

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Bral, Mariusz. Improving Clinical and Experimental Normothermic Ex situ Liver Perfusion For Future Application. Doctoral thesis, University of Alberta, 2019. https://doi.org/10.7939/r3-75yw-ez62