Back to search

University of Alberta

Infectious Prion Inactivation in Water and Wastewater

Abstract

dc:description.abstract

Misfolded prions (PrPSc) are well known for their resistance to conventional decontamination processes. The potential risk of contamination of the water environment, as a result of the disposal of specified risk materials (SRM), has raised public concerns. Ozone is commonly utilized in the water industry for the inactivation of microbial contaminants and was tested in this research for its ability to inactivate prions (263K hamster scrapie). With the applied ozone dose of 7.6-25.7 mg/L, the efficacy of ozone inactivation of PrPSc was both pH and temperature dependent. Treatment variables included applied ozone dose (7.6–25.7 mg/L), contact time (5 s and 5 min), temperature (4°C and 20°C) and pH (pH 4.4, 6.0, and 8.0). The inactivation of PrPSc was quantified by determining the in vitro destruction of PrPSc templating properties using the protein misfolding cyclic amplification (PMCA) assay and bioassay. Highest levels of prion inactivation (≥4-log) were observed with applied ozone doses of 13.0 and 25.7 mg/L, at pH 4.4 and 20°C. The kinetic modeling of prion inactivation in phosphate buffered saline (PBS) with applied ozone dose of 10.8 mg/L at pHs and temperatures described above was characterized by both Chick-Watson (CW) and efficiency factor Hom (EFH) models. It was found that the EFH model fit the experimental data more appropriately. Based on the EFH model, CT values were determined for 2-log, 3-log, and 4-log inactivation. A comparison of ozone CT requirements among various pathogens suggests that prions are more susceptible to ozone degradation than some model bacteria and protozoa. Subsequently, the ozone inactivation of infectious prions was assessed in the raw, gravity separated and dissolved air flotation (DAF) treated rendering wastewater, and in the municipal final effluent. It was found that the organic load highly affected prion inactivation by ozone, while DAF treatment significantly removed the organics and improved the efficacy. At the applied ozone dose of 44.6 mg/L, a >4-log inactivation was achieved after 5 min of exposure in the DAF treated rendering plant wastewater. The results indicated that ozone could serve as a final barrier for prion inactivation in primary and/or secondary treated wastewater.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Environmental Engineering
Grantor
University of Alberta
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ding, Ning
Advisors dc:contributor.advisor
  • Gamal El-Din, Mohamed (Civil and Environmental Engineering)
  • Belosevic, Miodrag (Biological Sciences)

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R3NG4GZ89

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Ding, Ning. Infectious Prion Inactivation in Water and Wastewater. Doctoral thesis, University of Alberta, 2013. https://doi.org/10.7939/R3NG4GZ89