Back to search

University of Alberta

Predicting Uterine Deformation Due to Applicator Insertion in Pre-Brachytherapy MRI Using Deep Learning

Abstract

dc:description.abstract

In locally advanced cervical cancer (LACC), brachytherapy (BT) remains the gold standard for boosting to curative doses in radiotherapy. Progress towards balancing target and routine tissue dosimetry for better clinical outcomes has been made possible by magnetic resonance imaging (MRI)-guided imaging data for treatment planning and by improving traditional BT applicator geometry. However, further evolving the original “one size fits all” approach towards truly personalized BT delivery requires improvements along the entire BT care pathway. From the pre-insertion applicator selection to the post-insertion treatment plan optimization, many factors need to be optimized for each patient for the best possible tumour and morbidity outcomes. The expanding collection and sharing of data, increased computational power in machine learning (ML) and artificial intelligence (AI), deep learning (DL) are rapidly transforming society, and offer the potential for similar transformation within health care. The success of these algorithms is founded on their judicious capability for detecting complex patterns even in heterogeneous datasets. This thesis aims to develop ML and DL-based models and free-form deformation methods for building predictive models to guide BT processes and decisions for consistently better personalization in LACC. First, an automated segmentation algorithm is proposed to delineate the uterus from the background on MRI using a deep convolutional neural network (CNN) architecture (Inception-V4) along with auto-encoders. After automated uterus segmentation, a modified version of another deep CNN model i.e., U-net is utilized to predict the at-BT uterus shape from pre-BT MRI. Finally, a shape-based non-rigid registration (free form deformation) algorithm is proposed to measure or quantify the amount of complex and large deformations of the uterus structure due to BT applicator insertion. The study deals with the very challenging and complex problem of predicting the large anatomical deformations from pelvic MR-images due to BT applicator insertion. The proposed method achieved an average Dice Coefficient of 94.8\\% and a Hausdorff distance of 3.06 mm, whereas the U-net yielded 92.4\\% and 6.7 mm for the Dice score and Hausdorff Distance metrics, respectively in the uterus segmentation task. The quantitative evaluations demonstrated that the proposed method performed significantly better than U-net in terms of both Dice Coefficient and Hausdorff Distance. After that, a pre-trained modified U-net is proposed to predict the at-BT uterus position from only the pre-BT MRI. This method yielded an average Dice score of 89.5\\% and a Hausdorff distance of 3.6 mm in predicting the uterine deformation automatically. Large anatomy deformations before and at the time of BT insertion were observed for most patients due to the insertion of the BT applicator. In order to quantify this deformation, a free-form deformation model-based non-rigid registration method is proposed. The applicator’s presence introduces a median uterine surface point-to-point displacement of 25.0 [10.0 - 62.5] mm and a median uterine cavity point-to-point displacement of 40.0 [12.0 - 68.0] mm from the pre-BT position. The challenge in implementing this algorithm was the inter-patient anatomical dissimilarity and extreme intra-patient uterine deformation from pre-BT to at-BT in the dataset. Increasing the size of our training dataset, with the inclusion of more heterogeneous images with anatomical variability, will improve the prediction accuracy of this DL-based algorithm. Our proposed DL-based model, despite being trained on heterogeneous and complex deformations, can successfully predict uterine distortion automatically due to applicator insertion using only the pre-BT MRI, which can guide the clinicians in selecting the most suitable applicator component and configuration ahead of the actual insertion procedure. These promise better, faster, and more streamlined clinical/technical decision-making before BT applicator insertion and plan optimization, potentially enabling more consistent application of BT personalization for LACC and improved dosimetric outcomes.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ghosh, Shrimanti
Advisors dc:contributor.advisor
  • Boulanger, Pierre (Computing Science)
  • Punithakumar, Kumar (Radiology, Computing Science)
  • Menon, Geetha (Oncology)

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/r3-zyqb-h385

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Ghosh, Shrimanti. Predicting Uterine Deformation Due to Applicator Insertion in Pre-Brachytherapy MRI Using Deep Learning. Doctoral thesis, University of Alberta, 2023. https://doi.org/10.7939/r3-zyqb-h385