Back to search

University of Alberta

Proposed Mixed-Method Study Design for the Assessment of Indoor Air Quality (IAQ) in Alberta Government Buildings for the Building Operators Management Association (BOMA)

Abstract

dc:description.abstract

The concepts of quantity and quality are implicitly implied in the term Indoor Air Quality (IAQ). The Building Environment Unit (BEU) of the Technical Services Branch of Alberta Infrastructure (AI) is a government group responsible for conducting IAQ Assessments in the Government of Alberta (GOA) owned and leased buildings. The BEU conducts IAQ assessments that are either reactive or proactive, with the first in response to an IAQ complaint and the latter as part of a regular inspection of the building’s parameters. In March 2011, the Building Operators Management Association contacted the BEU through another GOA department to undertake proactive verification of the air quality in selected GOA buildings as part of the BOMA BESt Initiative. Based on testing which occurred over approximately three (3) years in a wide variety of GOA buildings, as well as previous experiences and a review of recent IAQ literature, a cross-sectional, convergent-parallel, mixed-method study design for measuring both quantitative and qualitative information that may pertain to the perceived quality of the air inside GOA Buildings is proposed. The quantitative parameters proposed to be measured include: reviewing building documentation, inspecting the different components of the air handling unit(s), measuring Comfort Parameters, dust levels, airborne chemicals, supply and return airflow, and air pressurization in the occupied areas of the building. The qualitative measurements proposed to be observed include: interviewing the occupants of the building and asking them about their past and present perceptions and experiences concerning the building’s IAQ. Although the proposed BOMA IAQ Assessment method collects IAQ primarily on the day of the assessment, and is therefore prone to ‘Healthy Worker Bias’, the method is judged to be comprehensive and it provides ways to limit errors that may be caused by selection bias and confounding factors. One of these methods includes selecting random and non-random air sample locations within the building.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Environmental Health Sciences
Grantor
University of Alberta
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Brooks, Andrew M H
Advisor dc:contributor.advisor
  • Kindzierski, Warren (School of Public Health)

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R3HQ3S641

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Brooks, Andrew M H. Proposed Mixed-Method Study Design for the Assessment of Indoor Air Quality (IAQ) in Alberta Government Buildings for the Building Operators Management Association (BOMA). Master's thesis, University of Alberta, 2015. https://doi.org/10.7939/R3HQ3S641