Back to search

University of Alberta

The effects of stainless steel ligature ties on the mechanical characteristics of conventional and self-ligated brackets subjected to torque

Abstract

dc:description.abstract

Stainless steel ligatures ties are routinely used by orthodontists to improve torque; nevertheless, there is a lack of evidence as to the role of stainless steel ligation in bracket retentive characteristics. The objective of this study is to look into the effects of stainless steel (SS) ligation has on torque and bracket deformation for conventional and self-ligated brackets. A previously described torquing apparatus, combined with an overhead camera, utilized to rotate a .019x.025-inch stainless steel wire in a bracket slot to measure torque (Nmm) and acquire an overhead image at 3° increments of wire rotation from 0° up to 45°, and back again to 0°. A digital image correlation means and two profile images comparisons (before and after) were used to assess the structural changes of the bracket throughout the wire rotation and after the experiment, respectively Sixty Orthos®Twin brackets (Ormco Corp., Glendora, CA, USA), 30 ligated with conventional elastic ties and 30 ligated with SS ligature ties, and sicty Damon Q® brackets (Ormco Corp., Glendora, CA, USA), 30 ligated with its conventional sliding door and 30 ligated with SS ties in addition to the sliding door, were used. The torque was significantly higher for the steel ligated groups over conventional ones from 3°-9° of wire rotation. Overall, steel ligation did increase torque for Orthos twin brackets but it did not for Damon Q brackets. Stainless steel ligature reduces the amount of plastic deformation of both Orthos twin and Damon Q brackets, and a slight decrease in the slot width can be evident when stainless steel ligature is first applied to a bracket. SS ligature ties can be an effective auxiliary tool that could help practitioners to achieve better torque and to reduce bracket deformation

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Orthodontics
Grantor
University of Alberta
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Al Fakir, Hussam
Advisor dc:contributor.advisor
  • Paul Major (Department of Dentistry)

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R31Q1S

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Al Fakir, Hussam. The effects of stainless steel ligature ties on the mechanical characteristics of conventional and self-ligated brackets subjected to torque. Master's thesis, University of Alberta, 2012. https://doi.org/10.7939/R31Q1S