Back to search

University of Alberta

All-Optical and Endoscopic Photoacoustic Microscopy

Abstract

dc:description.abstract

Optical-resolution photoacoustic microscopy (OR-PAM) is a novel imaging technology providing high micron-scale lateral spatial resolution to visualize superficial structures in vivo with optical-absorption contrast. The term “optical resolution” is used since the lateral resolution of the system is defined by the optically-focused spot size, which is limited by the diffraction-limit of light. The axial resolution of the system is still inversely related to the bandwidth of transducer, typical of other photoacoustic microscopy (PAM) systems. Due to limitations of light transport, OR-PAM is used for imaging superficial structures to depths of about 1 mm in tissue. OR-PAM is able to image capillary networks and quantify morphological and functional parameters such as number of vessels, diameter and length of the vessels, total hemoglobin concentration and hemoglobin oxygen saturation. A tumor needs to develop angiogenesis in order to consume more oxygen and nutrients to grow. These blood vessels can provide imaging contrast for photoacoustic imaging, making OR-PAM a useful tool for tumor imaging. However there are several limitations with current OR-PAM systems. One of the limitations is their lack of flexibility. The present OR-PAM systems are mostly mounted as a table-top device with a large footprint. In this dissertation we introduce a label free optical-resolution photoacoustic micro-endoscopy to enable access to internal body cavities and a flexible handheld probe. Also, a multi-wavelength fiber laser with tunable repetition rates as high as 600 kHz, and high pulse-to pulse stability is demonstrated for in vivo real time functional imaging. This has been done by taking advantage of stimulated Raman scattering (SRS) in a single mode fiber. This system is also modified to perform a multi-focus OR-PAM by taking advantage of chromatic aberration in the collimating/objective lens pair to refocus light from a fiber into an object so that each iii wavelength is focused at a slightly different depth location. Design and fabrication of a novel Fabry-Perot etalon- based ultrasound detectors by using glancing angle deposition (GLAD) nanostructured thin-films is shown as well. Finally a novel all optical non-contact photoacoustic remote sensing (PARS) microscopy system is demonstrated with a lateral resolution as low as 2 μm. This system offers optical absorption contrast without the need of bulky ultrasound transducers or coupling medium and can provide performance comparable to previous OR-PAM systems but in a non-contact setting.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
University of Alberta
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Haji Reza, Parsin
Advisor dc:contributor.advisor
  • Roger Zemp

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R33N20N70

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Haji Reza, Parsin. All-Optical and Endoscopic Photoacoustic Microscopy. Doctoral thesis, University of Alberta, 2015. https://doi.org/10.7939/R33N20N70