Back to search

University of Alberta

Sodium MRI optimization for the human head with application to acute stroke

Abstract

dc:description.abstract

25 years after the first sodium images of the human brain were created, sodium MRI remains on the periphery of MR research, despite intimate sodium involvement in cellular metabolism and implicated abnormal concentrations in numerous disorders. The difficulties of sodium MRI include not only tissue concentration, ~1750x less than proton, but also rapid biexponential signal decay. The purpose of this work was to optimize human brain sodium MRI and facilitate a study of sodium increase following onset of acute human stroke, with potential ‘timing’ application for those patients who present with unknown time-of-onset, as effective treatment is currently bound by a 4.5 hour time-window. Optimization begins with radial ‘center-out’ k-space acquisition, which minimizes echo time (TE) and signal loss, and in particular concerns the twisted projection imaging (TPI) technique, which has not found wide use. This thesis first considers a new application of TPI, i.e. k-space filtering by sampling density design to minimize detrimental ringing artifact associated with cerebral spinal fluid. Image noise correlation is addressed next, and a method for measuring volumes of statistical noise independence presented, as this correlation together with signal-to-noise ratio (SNR) defines the confidence of signal-averaging measurements. Radial acquisition is then considered with respect to a new imaging metric, i.e. the minimum object volume that can be precisely (with respect to noise) and accurately (with respect to image intensity modulation with object volume) quantified. It is suggested that TPI is a highly beneficial radial acquisition technique when implemented with ‘long’ readout duration (countering common thought), reduced SNR (i.e. small voxel volumes), and in particular small TPI parameter p. Sequence optimization for bulk-tissue sodium analysis demonstrates a large SNR/voxel-volume advantage for TPI implementation in a steady-state approach, even though excitation pulse length and TE must be increased to mitigate power deposition. Finally, an inversion-recovery based fluid-nulling method that facilitates sodium environment separation based on rapid relaxation during soft inversion pulses is presented, with possible application for intracellular weighted imaging. On ‘high quality’ sodium images a clear trend of lesion intensity increase with time-after-onset is demonstrated for the first time in acute stroke patients, as expected from animal models.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stobbe, Robert
Advisors dc:contributor.advisor
  • Koles, Zoltan (Electrical and Computer Engineering)
  • Beaulieu, Christian (Biomedical Engineering)

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R30W3Z

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Stobbe, Robert. Sodium MRI optimization for the human head with application to acute stroke. Doctoral thesis, University of Alberta, 2010. https://doi.org/10.7939/R30W3Z