Back to search

University of Alberta

Temperature Control System Design for Flame-Sprayed Coating Based Heating Systems

Abstract

dc:description.abstract

A 2 cm thick American Iron and Steel Institute (AISI) 1018 steel sample was flame sprayed with Alumina (Al2O3) then a metal matrix composite consisting of Nickel-Chromium-Aluminum-Yttrium (NiCrAlY) and Alumina split 50 % by weight. A first order transfer function was derived from a lumped capacity model and was used to define parameters: time constant and gain which describe the dynamics of the heating system. Step inputs of 3, 6, and 9 V were applied to the heating element under internal forced convection heating conditions at an air temperature controlled to 15 ◦C. Temperature measurements were used to determine time constant, zero frequency gain, and confirm the Biot assumption. Heat transfer coefficient (HTC) dictating convective heat transfer rate was predicted from experimental measurements using the lumped capacity governing equation and a finite difference to describe the time derivative, values ranged from 208 W/m^(2)K and 250 W/m^(2)K. Experimental HTC was compared to theoretical HTC predictions showing a 40 % to 58 % difference. The resistance to temperature relationship for the coating material was measured using two voltage dividers in series. Results showed a maximum 2 % change in resistance over the experiment. Measured values were used in transfer function simulations to verify against experimental results, this showed that the linear model effectively predicts the non-linear system within the tested operating range. A sensitivity study shows the affect of uncertain parameters on transfer function predictions. Low uncertainty parameters are: area of the coated surface, density, thermal heat capacity, and thickness of the steel sample. High uncertainty parameters are: HTC and resistance across the flame sprayed Joule-heating element. After the transfer function was verified experimentally, it was used to design a temperature control system including a PI (Proportional integral) controller with windup control and input saturation management to provide a robust and energy efficient response.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Grantor
University of Alberta
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • John, Jacob Maxwell
Advisors dc:contributor.advisor
  • McDonald, Andre (Mechanical Engineering)
  • Rouhani, Hossein (Mechanical Engineering)

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Permission is hereby granted to the University of Alberta Libraries to reproduce single copies of this thesis and to lend or sell such copies for private, scholarly or scientific research purposes only. Where the thesis is converted to, or otherwise made available in digital form, the University of Alberta will advise potential users of the thesis of these terms. The author reserves all other publication and other rights in association with the copyright in the thesis and, except as herein before provided, neither the thesis nor any substantial portion thereof may be printed or otherwise reproduced in any material form whatsoever without the author's prior written permission.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/r3-9w6r-ks05

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

John, Jacob Maxwell. Temperature Control System Design for Flame-Sprayed Coating Based Heating Systems. Master's thesis, University of Alberta, 2020. https://doi.org/10.7939/r3-9w6r-ks05