Back to search

University of Alberta

A Low-voltage, Low-power Intraocular Pressure Measurement Instrument

Abstract

dc:description.abstract

Wireless sensing of abnormal intraocular pressure (IOP) levels associated with Glaucoma, a leading cause of blindness, was first proposed in the late 1960’s. While much research has been applied in the intervening time, a suitable commercially available wireless IOP monitoring instrument remains unavailable. The primary difficulty in developing a wireless IOP instrument is reduction of instrument size and power requirements. For implantation, the instrument is desired to be on the order of a few square millimeters. With such a small instrument, achieving biocompatible operation during electromagnetic field exposure necessary for inductively transferred wireless-power requires very low-power, low-voltage operation. This research presents a 325 mV, sub-μW capacitive-to-digital converter with power levels suitable for near-field wireless power operation with using an integrated circuit coil. This low-voltage, low-power operation creates the opportunity for a monolithic, millimeter-scale IOP monitoring instrument using integrated circuit technologies. The designed capacitive sensing circuitry uses Σ∆ modulation to perform capacitance-to-digital conversion. The modulator is implemented with fully-differential switched-capacitor circuits. Operational transconductance amplifiers required for the modulation are implemented with subthreshold inverters. Experimental test- ing shows the prototype instrument, comprised of the designed modulator and commercial capacitive pressure sensors, is capable of resolving 2.1 mmHg while operating at 325 mV using only 30 nW. In comparison with other systems in the field of IOP monitoring, this work represents the lowest operating voltage and power consumption reported to date.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
University of Alberta
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Davis, Caitlin
Advisors dc:contributor.advisor
  • Elliott, Duncan (Electrical and Computer Engineering)
  • Moez, Kambiz (Electrical and Computer Engineering)

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R3HQ2H

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Davis, Caitlin. A Low-voltage, Low-power Intraocular Pressure Measurement Instrument. Doctoral thesis, University of Alberta, 2014. https://doi.org/10.7939/R3HQ2H