Back to search

University of Alberta

Signal Compression Methods for Low-Power Implants

Abstract

dc:description.abstract

The pairing of implantable micro-electrode arrays with micro-electronic devices allows the observation of neural activity within nervous systems in a more comprehensive and potentially more effective way compared to single electrode recording. State-of-the-art tethered recording systems use implanted micro-electrode arrays and can record raw data rates of at least 24 Mbps over 100 channels. To make the systems fully implantable, the communication link needs to be wireless with the system power dissipation low enough for battery and/or near-field wireless operation. This thesis details a study of signal compression methods intended for implanted wireless low-power neural signal recording implementations. ASIC simulations of compression methods are presented for proof of concept and comparisons, while ASIC implementations provide power consumption measurements for select methods. It is shown by using a windowed noise-based dual-threshold neural spike detector that an energy savings of 90% can be expected compared to systems with no compression. Furthermore, an additional 80% compression per spike can be achieved using multilevel wavelet decomposition with no effect on the classification accuracy and relatively small increase in power consumption. Finally, a feature extraction method is presented and is simulated to demonstrate a neural spike compression ratio of 87% and classification accuracy of 96%.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Integrated Circuits and Systems
Grantor
University of Alberta
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dodd, Russell D
Advisor dc:contributor.advisor
  • Cockburn, Bruce (Electrical and Computer Engineering)

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R35X0Q

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Dodd, Russell D. Signal Compression Methods for Low-Power Implants. Doctoral thesis, University of Alberta, 2014. https://doi.org/10.7939/R35X0Q