University of Alberta
High-Temperature Thermal Gradient Interaction Chromatography (HT-TGIC) of Polyolefins: Effect of Polymer Molecular Weight, Comonomer Fraction, and Comonomer Type
Abstract
dc:description.abstractPolyolefins are the most important commodity polymers today. The demand for polyethylene and polypropylene, the two most important polyolefins, has been increasing steadily since their discovery in the late fifties. The properties of polyolefins is defined by their distributions of molecular weight (MWD), chemical composition (CCD), and long chain branching (LCB). The MWD is measured by hightemperature gel permeation chromatography (GPC). Several crystallization-based techniques, such as temperature rising elution fractionation (TREF), crystallization analysis fractionation (CRYSTAF), and crystallization elution fractionation (CEF), are used to measure the CCD of polyolefins. They are time consuming, prone to co-crystallization artifacts, and limited to lower comonomer fractions (< 15 mol%). High-temperature solvent gradient interaction chromatography (HT-SGIC) can also be used to measure the CCD of polyolefins and does not suffer from the limitations of crystallization-based methods, but it unfortunately uses two solvents (good/bad solvent) and non-quantitative evaporative light scattering detectors. A newly introduced technique, high-temperature thermal gradient interaction chromatography (HT-TGIC), is an attractive alternative because of its short analysis time and wide range of comonomer fractions. In addition, HT-TGIC uses only one solvent and can be combined with regular chromatographic detectors such as infrared detectors, refractometers, viscometers, and light scattering detectors. Previous HT-TGIC investigations were mostly limited to ethylene/1-octene copolymers with number average molecular weights (Mn) higher than 25 000. For these samples, Mn does not affect HT-TGIC fractionation, and peak temperatures display an inverse linear relation with comonomer fraction. ii The main objective of this thesis was to determine empirical calibration curves relating peak temperature to polymer Mw, comonomer fraction, and comonomer type using a set of ethylene/- olefin copolymers with Mn < 25 000 and different comonomer types (1-hexene, 1-octene, and 1- decene). The complementary objective of this thesis was to develop a new packing material for HT-TGIC columns. Conventional HT-TGIC columns are filled with porous graphite particles, which may have lower resolution due to size exclusion effects. The proposed novel packing material consisted of non-porous silica particles covered with graphene (GNPSi) to reduce size exclusion effects.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- chemical engineering
- Grantor
- University of Alberta
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Amirreza Badri
- Advisor dc:contributor.advisor
-
- Soares, João (Chemical and material engineering)
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/r3-ky86-t031