Back to search

University of Alberta

Strategies for Maximizing Signal to Noise in Decoupled Receive Coil Arrays for Magnetic Resonance Imaging

Abstract

dc:description.abstract

Designing radio frequency coil arrays for optimal Magnetic Resonance Imaging (MRI) has been a wide area of interest for many years. The optimum coil type for high density arrays and the mitigation of coupling between elements in arrays are significant problems addressed in this thesis. Coupling causes signal and noise transfer between coils, which affects optimum preamplifier noise matching, can cause resonant frequency splitting and degrade individual coil sensitivities. A theoretical framework for modeling capacitive coupling between array elements is developed and it is shown that coils can be completely decoupled by modified capacitive coupling without loss of SNR performance. Composite coils are three naturally decoupled orthogonal coils. During the design and testing of an 8-coil composite coil array their potential benefits in terms of SNR and parallel imaging are demonstrated. Also, composite arrays are compared to surface arrays with equal element count in relation to the maximum theoretical performance.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
University of Alberta
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Maunder, Adam M
Advisors dc:contributor.advisor
  • De Zanche, Nicola (Oncology)
  • Mousavi, Pedram (Electrical and Computer Engineering)
  • Daneshmand, Mojgan (Electrical and Computer Engineering)

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R3QN5ZK9C

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Maunder, Adam M. Strategies for Maximizing Signal to Noise in Decoupled Receive Coil Arrays for Magnetic Resonance Imaging. Master's thesis, University of Alberta, 2013. https://doi.org/10.7939/R3QN5ZK9C