Back to search

University of Alberta

The Effects of Elastic Size and Archwire Type on 3-Dimensional Force Systems When Using Class II Interarch Elastics

Abstract

dc:description.abstract

Abstract Objectives: An orthodontic simulator (OSIM) device was used to compare the force systems generated by class II elastics on a ½ cusp class II malocclusion using four combinations of two elastic types and two archwire types. Methods: 3-dimensional forces and moments due to class II elastics were measured individually for each tooth (7-7) using Damon Q brackets on the maxillary and mandibular arches. Four test groups (n=44) were compared, each of a different combination of two elastic types (3/16", 2oz and 4.5oz) and two archwire types (0.014" nickel titanium and 0.019" x 0.025" stainless steel). Results: Only the upper canines and lower first molars recorded clinically significant forces (0.3N) and moments (5Nmm). 2oz and 4.5oz class II elastics produced clinically significant vertical extrusive forces and horizontal forces along the archwire to normalize a class II malocclusion. Stainless steel archwire minimized the extrusive forces of the 4.5oz elastics compared to nickel titanium archwire Conclusions: 2oz and 4oz class II elastics produced clinically significant vertical extrusive forces and horizontal forces along the archwire. Archwire type had no effect on 2oz class II elastics whereas 0.019" x 0.025"stainless steel significantly reduced the vertical extrusive effects of the larger 4.5oz elastics.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Grantor
University of Alberta
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stanley, Joseph C
Advisor dc:contributor.advisor
  • Major, Paul (Dentistry)

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R3F766K4M

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Stanley, Joseph C. The Effects of Elastic Size and Archwire Type on 3-Dimensional Force Systems When Using Class II Interarch Elastics. Master's thesis, University of Alberta, 2017. https://doi.org/10.7939/R3F766K4M