Back to search

University of Alberta

Behaviour of Steel Plate Shear Walls Fabricated with Partially Encased Composite Columns

Abstract

dc:description.abstract

Partially encased composite columns consist of thin-walled built-up H-shaped steel sections with links welded near the flange tips and concrete cast between the flanges. The use of PEC columns under concentric axial load only was incorporated into the Canadian steel design standard, CAN/CSA S16-01, in 2001 and the use of PEC columns as beam-columns is permitted in the current edition, CSA S16-09 (CSA 2009). A half-size two-storey one-bay steel plate shear wall specimen, with PEC columns as the boundary elements, was tested under vertical and cyclic lateral loads to study its behaviour, and good ductility and performance was observed. A finite element model of the specimen was also developed and loaded in a push-over analysis with a dynamic explicit solution strategy to help study the behaviour of PEC columns and the whole system. The failure mode of the test specimen was the initiation of tears at the outside column flange tips at the bottom of the columns during the formation of plastic hinges. The specimen behaved in a ductile manner with no rapid drop of the specimen strength after the ultimate capacity was reached. Compared with steel plate shear walls with a steel frame, more nonlinear behaviours were observed in the specimen due to the existence of the concrete, which led to severely pinched hysteresis curves without a clear yield portion. Although the energy dissipation capacity did not keep increasing until the end of the test, it did increase beyond the value observed when the ultimate capacity was reached. Based on the test data, strain hardening occurred in the first floor infill panel and the corresponding finite element material curve was modified accordingly. In general, the model gave good predictions of the overall specimen behaviour and internal frame forces.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Structural Engineering
Grantor
University of Alberta
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Deng, Xiaoyan
Advisor dc:contributor.advisor
  • Driver, Robert G. (Civil and Environmental Engineering)

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R38G6F

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Deng, Xiaoyan. Behaviour of Steel Plate Shear Walls Fabricated with Partially Encased Composite Columns. Doctoral thesis, University of Alberta, 2012. https://doi.org/10.7939/R38G6F