Back to search

University of Alberta

Long-term Performance of Timber-concrete Composite Systems with Self-tapping Screws Connections

Abstract

dc:description.abstract

Timber-concrete composite (TCC) systems combine timber and concrete to leverage their respective advantages. This composite structure enhances strength and stiffness, making TCC systems suitable for a range of applications. Despite their advantages, the design of TCC systems is often governed by Serviceability Limit States due to the rheological characteristics of the materials involved. Long-term deformations in TCC systems are influenced by sustained loading and environmental changes, as both timber and concrete are susceptible to creep and shrinkage thus effective connection between these materials is crucial for ensuring the systems’ optimal short- and long-term performance. Recent research has shown that self-tapping screws offer superior load-bearing capacity and reduced slip compared to traditional connectors, especially when inserted at an angle to the shear plane. Despite this, there remains a gap in understanding the long-term performance of these connections, and current design standards do not fully address this aspect, highlighting the need for further investigation into long-term deformations of TCC. This study was divided into experimental and analytical phases. Experimental work involved the fabrication of TCC connection specimens with self-tapping screws inserted at various angles to the shear plane and with different nominal diameters. Preliminary tests assessed the shear strength, stiffness, and failure modes of different configurations and the results were compared with analytical models. Next, the specimens were subjected to a sustained load for six months to determine the creep coefficient, with the creep curves extrapolated to predict the 50-year creep coefficient. Destructive tests followed to evaluate the impact of long-term loading on specimen strength and stiffness. Short-term tests showed that inclined screws provided greater strength and stiffness but exhibited reduced ductility compared to perpendicular screws, in which the failure mode was the formation of two plastic hinges. Long-term creep tests, conducted under uncontrolled indoor environmental conditions, revealed that minor fluctuations in temperature and humidity did not influence the connection’s creep coefficient. Results also revealed that 90-degree screws showed more instantaneous slip and a faster initial increase in creep coefficient, due to their dependence on bearing resistance, while inclined screws benefited from both bearing and withdrawal resistances. Also, the generalized Kelvin model effectively captured the creep behaviour. While the six-month sustained loading did not affect the connection strength, it did reduce connection stiffness, highlighting the need for better predictive models that account for long-term deflections. An analytical model was used which was capable of modeling the final midspan deflection of TCC systems considering the sustained load and concrete shrinkage. This model showed that neglecting the concrete shrinkage can lead to underestimation of the final deflection. The parametric study based on this analytical model showed that geometric parameters, particularly span, had greater impact on long-term deflection than material properties. The type of connection also influences the total deflection, with inclined screws reducing deflection due to their higher stiffness and lower creep coefficient. However, concrete shrinkage exerts a greater impact on stiffer connections, necessitating a careful balance between these parameters.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Structural Engineering
Grantor
University of Alberta
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Esmaeildoust, Shadi
Advisors dc:contributor.advisor
  • Tomlinson, Douglas (Civil and Environmental Engineering)
  • Chui, Ying Hei (Civil and Environmental Engineering)

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/r3-b9b9-n808

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Esmaeildoust, Shadi. Long-term Performance of Timber-concrete Composite Systems with Self-tapping Screws Connections. Master's thesis, University of Alberta, 2024. https://doi.org/10.7939/r3-b9b9-n808