University of Alberta
The Development of a Polymer Thin Film as a Point-of-Care Diagnostic Based on Affinity Protein Separation
Abstract
dc:description.abstractThin film interference provides a qualitative means of detection for a new generation of highly sensitive POC diagnostics. The purpose of this work was to demonstrate that thin-film diagnostic technology can be: (1) highly sensitive and stand-alone as a POC diagnostic device; (2) capable of testing low-concentration, small- and large-volume sample sizes and (3) uses thinfilm interference colour shift principles as a detection method. The device functions by immobilizing an antibody on an aluminum oxide-covered poly-methyl-methacrylate surface and then exposing the surface to a high-volume fluid sample containing the corresponding antibody at a low concentration using an optimized conical draft tube apparatus. Binding leads to the formation of an antigen-antibody complex, which induces a visible colour shift on the device surface due to an increase in the optical path length. The limits of detection of the polymer-based diagnostic were determined for a stationary 20 µL fluid sample and a 500 mL fluid sample travelling through an optimized draft tube apparatus. The polymer-based diagnostic had a limit of detection of 0.05 mg/mL (0.33 µM) in a stationary 20 µL fluid sample of anti-prothrombin. Using the optimized conical draft tube apparatus, the diagnostic device detected antiprothrombin in a 500 mL solution at a concentration of 6.25x10-8 mg/mL (0.42 pM) after a 20- minute exposure. This was an 800,000-fold improvement in sensitivity compared to the stationary drop and a 10-fold improvement compared to previous iterations of an anodizedaluminum diagnostic. Additionally, this diagnostic had a 1.6-fold increase in sensitivity in comparison to an example of a standard enzyme-linked immunosorbent assay (ELISA) test. In conclusion, the polymer-based diagnostic could detect anti-prothrombin in high-volume, lowconcentration fluid samples, which was quantified by a colour shift on the surface of the wafer after a 20-minute exposure. Optimizing the conical draft tube to maximize turbulent flow through the draft tube and on the surface of the wafer improved the device sensitivity by a factor of 800,000.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Grantor
- University of Alberta
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Denton, Ryan James
- Advisor dc:contributor.advisor
-
- Burrell, Robert (Biomedical Engineering)
Subjects
dc:subject × 11Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/r3-xfrj-gg96