dc:description.abstract

This study is a part of a field experiment constructed at the Diavik Diamond Mine in northern Canada to investigate water flow, geochemical reactions, thermal and gas transport within unsaturated piles of mine waste rock in a continuous permafrost permafrost. Diavik waste rock is categorized by its sulfur content: Type I rock, Type II rock and Type III rock . Three experiment waste-rock piles of 15 m high were constructed to achieve the project objectives. Two uncovered test piles are referred to as Type I test pile (Type I rock) and Type III test pile (Type III rock). The third test pile is covered test pile in which the Type III rock is covered by a layer of 1.5 m till and 3 m Type I rock. Three drill holes of 40 m depth in a 80 m high pile were also instrumented to reexamine the results of the test piles. This thesis focuses on the thermal aspects of the project. Thermal measurements in the uncovered piles implied the importance of wind on heat transport. Temperatures within the piles were found to decrease with time and permafrost aggradation near the base and in bedrock foundation. At the covered pile, temperatures at and below the till cover were frozen. There was no significant impact of wind on temperatures below the cover and heat influx across the cover was small. Bedrock foundation temperature of the covered pile showed a small cooling trend and less fluctuation compared to bedrock foundation of the uncovered piles. Linear stability analysis for the onset of natural air convection in waste-rock piles with physical properties based on Diavik waste rock was also performed. The results indicate that oxidation can create sufficient temperature gradients (or buoyancy forces) to trigger natural air convection. Ground temperatures of three 40 m drill hole in the 80 m high full-scale pile showed that conduction was dominated and the pile was cooling. According to numerical simulations, using air convection cover (ACC) the 80 m high pile will be frozen for the next 100 years under a proposed climate warming for the site. Furthermore, numerical simulations also showed that ACC can maintain frozen condition within waste-rock piles even though there was a heat release due to sulfide oxidation. This heat release may create natural air convection within waste-rock piles which aids in its removal.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Geotechnical Engineering
Grantor
University of Alberta
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pham, Hoang Nam
Advisors dc:contributor.advisor
  • Sego, Dave (Civil and Environmental Engineering)
  • Wilson, Ward (Civil and Environmental Engineering)

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Libraries with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/R3V30N

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Pham, Hoang Nam. HEAT TRANSFER IN WASTE-ROCK PILES CONSTRUCTED IN A CONTINUOUS PERMAFROST REGION. Doctoral thesis, University of Alberta, 2013. https://doi.org/10.7939/R3V30N