Back to search

University of Alberta

Zero-Sequence-Voltage-Based Detection and Localization Schemes for False Data Injection Attacks in Multiphase Power Distribution Systems

Abstract

dc:description.abstract

Modern power systems are vulnerable to false data injection attacks (FDIAs) due to the widespread applications of two-way communication networks for system operation and control. Diagnosing such malicious attacks are of great significance for the resilient operations of power systems. Firstly, to detect the presence of FDIAs, a novel FDIA detection scheme is proposed in this thesis for three-phase distribution systems based on zero-sequence voltage (ZSV). From the voltage and power measurements, the bus voltages are estimated, and then the estimated ZSV is calculated as the sum of the estimated bus voltages on the three phases to represent the degree of unbalance of the distribution system. Via mathematical analysis of the linear distribution system state estimation (DSSE) model, the distribution of the estimated ZSV under the normal condition is derived, based on which a whitening process is adopted on the estimated ZSV to weaken the effect of measurement noises. The L2-norm of the whitened ZSV vector is then compared with a predefined threshold for the FDIA detection. Moreover, the probability of false alarm of the proposed scheme is derived, which can be utilized to determine the detection threshold for a desired tolerance of false alarm rate. The proposed FDIA detection scheme is validated on several IEEE Test Feeders and simulation results show the effectiveness of the proposed scheme in detecting FDIAs in three-phase distribution systems. To further specify the locations of FDIAs, a ZSV-based FDIA localization scheme is also proposed in this thesis for three-phase distribution systems. Based on the estimated ZSV of a bus relative to others, the bus under attack is localized. By eliminating the effect of estimation error, an estimation of the injected attack is obtained. With an optimal test to minimize the error rate, the phase under attack can be diagnosed. By analyzing the estimated ZSV values in three steps, the bus localization and phase diagnosis can be achieved. Simulation results verify the effectiveness of the proposed FDIA localization method with high accuracy.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Communications
Grantor
University of Alberta
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ma,Chengran
Advisors dc:contributor.advisor
  • Yindi Jing (Electrical and Computer Engineering)
  • Hao Liang (Electrical and Computer Engineering)

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/r3-27zp-2h82

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Ma,Chengran. Zero-Sequence-Voltage-Based Detection and Localization Schemes for False Data Injection Attacks in Multiphase Power Distribution Systems. Master's thesis, University of Alberta, 2022. https://doi.org/10.7939/r3-27zp-2h82