Back to search

University of Arkansas

Aptamer-based SPR Biosensor for Detection of Avian Influenza Virus

Abstract

dc:description.abstract

Rapid and specific detection of avian influenza (AI) virus is urgently needed with the concerns over the outbreaks of highly pathogenic H5N1 avian influenza in animal and human infection. Aptamers are artificial oligonucleic acid that can specifically bind to target molecules. They show comparable affinity for target virus and better thermal stability than monoclonal antibodies. Those advantages make aptamers promising candidates in diagnostic and detection applications. The goal of this research was to use DNA&ndashaptamer as the specific recognition element in a portable surface plasmon resonance (SPR) biosensor for detection of AI H5N1 virus in poultry. A SPR biosensor was fabricated using the selected aptamers based on streptavidin&ndashbiotin method. Streptavidin was directly adsorbed onto the surface of a gold waveguide in the SPR biosensor. Then, biotinylated aptamers were immobilized on the sensor surface via streptavidin&ndashbiotin binding. The immobilized aptamers captured AI H5N1 virus in a sample solution, causing an increase in refraction index (RI). Performances of the aptamer&ndashbased SPR biosensor were studied in streptavidin modification, aptamer immobilization and virus detection. The optimal concentrations of streptavidin and aptamers were determined to improve the sensitivity of the biosensor. The response of the aptamer&ndashvirus interaction was shown to be virus titer&ndashdependent, and a linear range for the titers of AI H5N1 was found between 0.128 and 1.28 HA unit. The aptamer&ndashbased SPR biosensor could detect the H5N1 virus at a titer greater than 0.128 HA unit within 1.5 h. No significant interference was observed from non&ndashtarget subtypes such as AI H7N2, H9N2, H2N2, H1N1 and H5N2. The aptamer&ndashbased SPR biosensor was further evaluated for detection of AI virus in poultry swab samples. All of the AI viruses used in this study were killed ones to ensure biological safety.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biological Engineering (MSBE)
Level thesis:degree_level
Thesis
Department thesis:degree_department
Biological and Agricultural Engineering
Year dc:date.available
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bai, Hua
Advisor dc:contributor.advisor
  • Li, Yanbin
Contributors dc:contributor
  • Ye, Kaiming
  • Erf, Gisela F.

Subjects

dc:subject × 9

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarworks.uark.edu/etd/409

Chain of custody

source
Harvested from
University of Arkansas
Base URL
scholarworks.uark.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bai, Hua. Aptamer-based SPR Biosensor for Detection of Avian Influenza Virus. Thesis thesis, 2012. https://scholarworks.uark.edu/etd/409