Back to search

University of Arkansas

Modified-Electrodes for Redox-Magnetohydrodynamic (MHD) Pumping for Microfluidic Applications

Abstract

dc:description.abstract

A new microfluidic pumping and stirring technique was demonstrated for lab-on-a-chip applications. Microfluidics was accomplished via redox-MHD, which takes advantage of a body force (FB) that is generated when there is a net movement of ions in solution (j) in the presence of a perpendicular magnetic field (B), according to the equation FB = j×B. In this work the movement of ions in solution was generated using electrodes modified with the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) rather than a redox species in solution, which can interfere with analyte detection and with biological species. The monomer solution and electrochemical method used for electrodeposition has a profound effect on the morphology and the electrochemical behavior of the film. These conditions were investigated to improve the properties of the PEDOT film for redox-MHD applications, such as coulombic capacity, current response, and electrochemical stability. PEDOT-modified microband electrodes were shown to be effective for microfluidic pumping applications, exhibiting a fairly flat flow across a 5600 μm gap. PEDOT-modified concentric ring-disk electrodes demonstrated a rotational fluid flow with nonuniform velocity between the disk and ring electrodes. This created a spiraling fluid flow that could be useful for stirring applications. PEDOT-modified electrodes were shown to be capable of initially high currents, and therefore velocities (up to 980 μm s-1 at microband electrodes during an applied potential experiment), until the film was exhausted, limiting the time scale of pumping. This limitation was solved by taking advantage of the reversible nature of PEDOT. The bias of the PEDOT-modified electrodes was switched by applying a sinusoidal potential waveform while a synchronized potential waveform was driving an electromagnet under the chip, creating an AC magnetic field. This generated continuous fluid flow in a single direction. AC redox-MHD pumping was demonstrated at PEDOT-modified microband electrodes (115 μm s-1) and at concentric ring-disk electrodes (<268 μm s-1) for pumping and stirring applications respectively.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy in Chemistry (PhD)
Level thesis:degree_level
Dissertation
Department thesis:degree_department
Chemistry & Biochemistry
Year dc:date.available
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nash, Christena Kayl
Advisor dc:contributor.advisor
  • Fritsch, Ingrid
Contributors dc:contributor
  • Durham, Bill
  • Paul, David W.

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarworks.uark.edu/etd/2172

Chain of custody

source
Harvested from
University of Arkansas
Base URL
scholarworks.uark.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Nash, Christena Kayl. Modified-Electrodes for Redox-Magnetohydrodynamic (MHD) Pumping for Microfluidic Applications. Dissertation thesis, 2014. https://scholarworks.uark.edu/etd/2172