Back to search

University of Arkansas

Toward a Better Understanding of Friction, Adhesion, and Stud Bearing Shear Transfer at the Steel-Concrete Interface of Composite Bridge Girders

Abstract

dc:description.abstract

Following curing of the concrete deck, load transfer between the concrete and steel components in a composite bridge girder is possible through three mechanisms: 1) mechanical contact (bearing) between the embedded shear connectors and surrounding cured concrete, 2) adhesion between the cured concrete and steel-section top flange, and 3) friction between the contacting materials Understanding the mechanisms of bearing, adhesion, and friction shear transfer at the steel-concrete interface of composite bridge girders is necessary for efficient proportioning of headed shear connectors (or studs) in design. To better understand the roles that stud bearing, adhesion, and friction play in composite girder load transfer, a two-part experimental program is executed in this study, involving 1) component-scale laboratory testing (isolating a section of composite girder) under controlled direct shear loading, and 2) full-scale girder testing under combined flexure and shear loading. Various instrumentations, including thin foil pressure gauges mounted to the embedded shear studs are used to measure stud demands. Results from the direct shear and flexure testing indicate that uncoated flanges in composite girders (having an SP-10 blast cleaned surface) experience lower stud demands than those currently predicted by the AASHTO specification. This is likely due to a complex girder-to-slab interface condition (interface interlocking) that is created during adhesion breakage resulting in a baseline stud demand reduction of 42%. Coating of the steel flange (application of a paint primer) prior to concrete casting likely affects the beneficial load transfer interface that is created following adhesion loss and can be expected to result in higher stud demands than those created from uncoated/un-primed flange conditions. For coated flanges, an interface friction reduction percentage equal to 2*N% is recommended, where N is the tributary slab and overlay dead load in kips/ft. Implementation of the stud demand reduction in a case-study re-design of the James Street bridge in Jacksonville, Arkansas, show a 27.7% and 29.2% reduction in the number of required shear studs for a composite bridge having uncoated exterior and interior girders respectively.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy in Engineering (PhD)
Level thesis:degree_level
Dissertation
Department thesis:degree_department
Civil Engineering
Year dc:date.available
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • James, Callie Grace
Advisor dc:contributor.advisor
  • Prinz, Gary
Contributors dc:contributor
  • Murray, Cameron
  • Hebdon, Matt

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarworks.uark.edu/etd/6043

Chain of custody

source
Harvested from
University of Arkansas
Base URL
scholarworks.uark.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

James, Callie Grace. Toward a Better Understanding of Friction, Adhesion, and Stud Bearing Shear Transfer at the Steel-Concrete Interface of Composite Bridge Girders. Dissertation thesis, 2025. https://scholarworks.uark.edu/etd/6043