Back to search

University of Arkansas

Advancement in Electrochemical Generation-Collection: Snapshot Redox Cycling Voltammetry for Rapid Analysis at Chip-Based, Individually Addressable Microband Electrode Arrays

Abstract

dc:description.abstract

Snapshot redox cycling voltammetry (Snapshot RCV) is introduced as a rapid electrochemical technique that reconstructs the current-potential profile of a redox active species using a microband electrode array. By simultaneously biasing individual generator electrodes alternating in the array to different voltages across the analyte’s potential range while individually holding collector electrodes at a reversing potential, “spatial” voltammetry is achieved in as little as 1 s with the temporal speed of chronoamperometry, rapidly capturing the steady-state redox cycling (RC) profiles. During RC (a mode of generation-collection), the analyte is oxidized (or reduced) at generator electrodes and converted back at neighboring collector electrodes held at a constant potential, yielding two current signals. This reveals information about diffusion-dominated systems, heterogeneous electron transfer kinetics, and following chemical reactions. Furthermore, as electrode spacing decreases, current amplifies from overlapping diffusion layers that increase concentration gradients. In contrast to conventional RC voltammetry (Conventional RCV) that slowly sweeps the generator potential, Snapshot RCV applies a distribution of potentials across individual generator electrodes instead. Snapshot RCV was validated using 0.50 mM Ru(NH3)6Cl3 in 0.10 M KCl on a seven-electrode subset of a nine-electrode gold microband chip, (NE = 7, w = 4.08 µm, wgap = 4.14 µm, length = 97.17 µm). Snapshot RCV was then applied to pure solutions of 0.50 mM dopamine (DA), 3,4-dihydroxyphenylalanine (L-DOPA), 3,4-dihydroxyphenylacetic acid (DOPAC), and ascorbic acid (AA) in artificial cerebral spinal fluid (aCSF). This applies the technique to systems where subsequent chemical reactions lower collection efficiency (DA, L-DOPA, DOPAC), or where irreversible products are generated (AA). Snapshot RCV is shown to capture the voltammetric shape for the electrochemical behavior of the analyte with an increase in collection efficiency by 10%-60% over Conventional RCV. This distinction in collection efficiencies and response shapes of biologically relevant molecules, driven by their thermodynamics, kinetics, and following chemical mechanisms could make Snapshot RCV a promising qualitative and quantitative technique, enabling rapid sensing in confined spaces.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Chemistry (MS)
Level thesis:degree_level
Thesis
Department thesis:degree_department
Chemistry & Biochemistry
Year dc:date.available
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sterling, Blake Aleck
Advisor dc:contributor.advisor
  • Fritsch, Ingrid
Contributors dc:contributor
  • Dong, Bin
  • Stenken, Julie

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarworks.uark.edu/etd/6151

Chain of custody

source
Harvested from
University of Arkansas
Base URL
scholarworks.uark.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sterling, Blake Aleck. Advancement in Electrochemical Generation-Collection: Snapshot Redox Cycling Voltammetry for Rapid Analysis at Chip-Based, Individually Addressable Microband Electrode Arrays. Thesis thesis, 2026. https://scholarworks.uark.edu/etd/6151