Back to search

University of Arkansas

Coupled Effects of Sub-Atmospheric Pressure and Surface Structures on Pool Boiling Performance and Hysteresis Pathways

Abstract

dc:description.abstract

The increasing power density of microelectronics has created a need for cooling technologies capable of maintaining low operating temperatures. Sub-atmospheric pool boiling of water is promising because reducing saturation pressure lowers the boiling temperature, enabling two phase cooling within electronics-relevant temperature limits. However, reduced pressure also affects CHF, HTC, and post-CHF recovery. In this work, pool boiling experiments were conducted on flat copper, microchannel copper, and micro-pin-fin copper surfaces over 10–100 kPa to examine the coupled effects of pressure and surface structure. CHF and HTC increased with pressure, while structured surfaces enhanced both relative to flat copper. Surface structure dominated CHF enhancement, with structured surfaces at 10 kPa exceeding the CHF of flat copper near atmospheric pressure, whereas HTC depended on both pressure and surface structure. Post-CHF analysis showed that boiling hysteresis was reduced at lower pressures, especially from 10–30 kPa, allowing faster recovery to nucleate boiling. The hysteresis ratio, �� =��"NBR/��"CHF, collapsed with maximum post-CHF wall superheat, indicating that recovery is governed by the thermal maturity of the CHF-generated vapor/dry state. High-speed imaging and BubbleID segmentation supported this interpretation by showing vapor persistence and rewetting. Overall, sub-atmospheric pressure operation combined with surface micro-structuring provides a viable pathway for high-performance water-based cooling of high-power-density electronics.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Mechanical Engineering (MSME)
Level thesis:degree_level
Thesis
Department thesis:degree_department
Mechanical Engineering
Year dc:date.available
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hossain, Mohammad Ishraq
Advisor dc:contributor.advisor
  • Hu, Han
Contributors dc:contributor
  • Huitink, David
  • Walters, Keith

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarworks.uark.edu/etd/6412

Chain of custody

source
Harvested from
University of Arkansas
Base URL
scholarworks.uark.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hossain, Mohammad Ishraq. Coupled Effects of Sub-Atmospheric Pressure and Surface Structures on Pool Boiling Performance and Hysteresis Pathways. Thesis thesis, 2026. https://scholarworks.uark.edu/etd/6412