Some of the Corneal Effects Produced by Wearing Hydrogel Contact Lenses Soaked in a Non-Isotonic Saline

Abstract

dc:description.abstract

The corneal response to daily and extended wear hydrogel contact lenses was evaluated when the lenses were soaked in non-isotonic solutions varying from 0.7 to 1.2 percent. The naturally occuring diurnal variations of the cornea were examined to discover what effect they may have on contact lens wear. It was noted that there were significant corneal hydration changes. Initially there was swelling of the cornea which subsided after four hours. There were no changes in the central anterior radius of the cornea. No realtionship could be found between intraocular pressure and corneal hydration in different Ves. It appears that intraocular pressure is an independent parameter...

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Aston University
Year dc:date.issued
1983

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kempster, Angela J.

Rights

Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Aston University
Base URL
publications.aston.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kempster, Angela J.. Some of the Corneal Effects Produced by Wearing Hydrogel Contact Lenses Soaked in a Non-Isotonic Saline. doctoral thesis, Aston University, 1983. https://doi.org/10.48780/publications.aston.ac.uk.00014593