Back to search

Aston University

The single axis d.c. machine as a control system element

Abstract

dc:description.abstract

The interaction between the direct- axis flux and quad- rature-axis flux, which is brought about by magnetic saturation, makes the prediction of machine transient performance a difficult proposition. This factor was treated as having prime importance, but other non-linearities were considered as well, in developing the mathematical model of the machine. The model was treated as a multi- variable non-linear control system for analysis by numerical methods. Results from the analysis indicate that a reasonably accurate prediction of performance was obtained over a wide range of initial conditions. A method was then evolved, using a hill climbing technique, which enabled prediction of the control strategy required to optimise to a desired transient performance.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Aston University
Year dc:date.issued
1969

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Johnson, R.C.

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
Aston University
Base URL
publications.aston.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Johnson, R.C.. The single axis d.c. machine as a control system element. doctoral thesis, Aston University, 1969.