Back to search

University of Bath

Flow and heat transfer in a pre-swirl rotor-stator system

Abstract

dc:description.abstract

<p>This thesis describes the computational study of the flow and heat transfer in a direct-transfer pre-swirl rotor-stator system. Pre-swirl cooling air enters the system at low radius through angled pre-swirl nozzles, located on the stator, impinges on the rotor and flows outward in the wheel-space between stator and rotor, and leaves the system through receiver holes, located on the rotor.</p> <p>Computations were carried out using a 3D incompressible model, with one discrete pre-swirl nozzle on the stator and cyclic symmetry boundary conditions applied at the tangential faces of the domain. To permit steady-state computations, an annular outlet was used on the rotor that matched the centerline radius and total area of the receiver holes. The Reynolds-averaged Navier-Stokes equations in cylindrical polar coordinates were solved in primitive-variables using the finite-volume method, hybrid differencing and the SIMPLE pressure-correction scheme. The low-Reynolds-number Launder-Sharma turbulence model was used primarily and the Morse <i>κ</i> – <i>ε</i> model was also tested.</p> <p>An axisymmetric numerical investigation was conducted to study the effect of the swirl ratio and other flow parameters on the flow and heat transfer in system, with computation times reduced by a factor of around 7 compared with the corresponding 3D computations.</p> <p>The computations were also compared with data obtained from a complementary experimental study. The range of flow parameters tested in the experiments and used in the computations were: for rotational Reynolds numbers, 0.77×10<sup>6</sup> < <i>Re<sub>φ</sub></i> < 1.2×10<sup>6</sup>; for non-dimensional pre-swirl flow rates, 0.6×10<sup>4</sup> < <i>c<sub>w,p</sub></i> < 2.8×10<sup>4</sup> (giving 0.12 <i>λ<sub>T,p</sub></i> = <i>c<sub>w,p</sub>Re<sub>φ</sub></i><sup>-0.8</sup> < 0.4); for pre-swirl ratio, 0.5 < <i>β<sub>p</sub></i> < 3.</p> <p>The computed and measured values of (tangentially-averaged) non-dimensional tangential velocity, <i>V<sub>φ</sub></i>/Ω<i>r</i>, and static and total pressure coefficient are mainly in good agreement. The computed results suggest that free-vortex flow occurs between the pre-swirl inlets and the receiver outlet. The results show a significant loss in total pressure near the pre-swirl inlets. An expression has been derived for calculating the discharge coefficient for the receiver outlet, and there is good agreement between measured and computed values.</p> <p>The computed local Nusselt number, <i>Nu</i>, is compared with measured values. There is reasonably good agreement between computation and measurement for the level of <i>Nu</i> apart from the impingement region and radially outward of the receiver outlet. There is a large peak in <i>Nu</i> near the inlet radius, due the behaviour of the low-Reynolds number turbulence model in the impingement region. The measured effects of <i>Re<sub>φ</sub></i>, <i>λ<sub>T,p</sub></i> and <i>β<sub>p</sub></i> on the level of <i>Nu</i> are reproduced well by the computations.</p>

Degree

thesis:*
Name dc:type.qualificationname
PhD
Level dc:type.qualificationlevel
Doctoral Thesis
Grantor dc:publisher.institution
University of Bath
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Farzaneh-Gord, Mahmood
Advisors dc:contributor.advisor
  • Wilson, Michael
  • Owen, John

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
oai:purehost.bath.ac.uk:studenttheses/304c80c7-522c-4bd4-92f1-e5b15246df80

Chain of custody

source
Harvested from
University of Bath
Base URL
purehost.bath.ac.uk/ws/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Farzaneh-Gord, Mahmood. Flow and heat transfer in a pre-swirl rotor-stator system. Doctoral Thesis thesis, University of Bath, 2003. https://researchportal.bath.ac.uk/en/studentTheses/304c80c7-522c-4bd4-92f1-e5b15246df80