Back to search

University of Bath

Distributor design and its effect on a fluidised bed reactor.

Abstract

dc:description.abstract

The design of multi-orifice gas distributors and the effect of the distributor on the physical and chemical behaviour of a large two-dimensional fluidised bed reactor were studied. A rational procedure was proposed for the design of multi-orifice distributors. A new model was proposed to determine the necessary minimum distributor pressure drop. Model predictions were in good agreement with experimental data. Experimental work was carried out to examine the effect of five different multi-orifice distributors on the catalytic decomposition of ozone. For values of the dimensionless rate constant, NR greater than 1.0, the number of orifices, N, had a significant effect on conversion. Reactor conversion increased as N increased. The distributor with 25 orifices represented the limiting value of N, in terms of the influence of the distributor on reactor performance. Jet penetration and mass transfer were studied in a small two-dimensional fluidised bed. The results showed that jet penetration in two-dimensional beds was greater than that in three-dimensional beds. The measured rates of mass transfer were considerably less than those predicted by the empirical equation of Behie et al(17) , but were of similar magnitude to the rates of mass transfer associated with the bubble phase close to the grid. A model, developed to describe the jetting region, was found to underestimate both gas- solid contacting and mass transfer, particularly in the upper portion of the jet which fluctuated rapidly in shape and height. The jetting region was satisfactorily described using the equations for the bubbling region of the bed. A new model was proposed to explain the discrepancy between the observed visible gas flow and that predicted by the two-phase theories. This discrepancy was accounted for by a combination of an increased cloud size and gas short-circuiting through bubble chains. Two reactor models in literature were modified and the predictions compared with experimental data. The modified Kunii and Levenspiel model indicated that an increased cloud size was predominant, while the modified Orcutt and Davidson model suggested that gas 'short- circuiting' was more probable. It was not the aim of the present study to discriminate between reactor models and therefore no definite conclusion was drawn in favour of one model or the other. Evidence from literature suggests that the former model provides a more realistic account of gas-solid contacting and mass-transfer between the phases.

Degree

thesis:*
Name dc:type.qualificationname
PhD
Level dc:type.qualificationlevel
Doctoral Thesis
Grantor dc:publisher.institution
University of Bath
Year dc:date.issued
1981

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kolaczkowski, J. A.

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
oai:purehost.bath.ac.uk:studenttheses/a435e774-8ea2-4b4a-acd6-832d87f9212b

Chain of custody

source
Harvested from
University of Bath
Base URL
purehost.bath.ac.uk/ws/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
related terms
citation

Kolaczkowski, J. A.. Distributor design and its effect on a fluidised bed reactor.. Doctoral Thesis thesis, University of Bath, 1981. https://researchportal.bath.ac.uk/en/studentTheses/a435e774-8ea2-4b4a-acd6-832d87f9212b