Baylor University.
Variation of cold-soaked fuel frost roughness with location on a flat plate.
Abstract
dc:description.abstractCold-soaked fuel frost occurs when moist air flows over an aircraft surface that is colder than the dew point temperature following a flight. Previous studies show that cold-soaked fuel frost depends on surface temperature, air temperature, surface geometry, exposure time, and Reynolds number. However, variation in frost roughness due to location on a plate is not well established for surfaces which scale to sizes expected for commercial aviation. In this thesis, photogrammetry and infrared imaging are used to characterize cold-soaked fuel frost roughness. The roughness variation is explained by the viscous and thermal boundary layer development. The roughness measurements from this study suggests that frost forms rapidly towards the leading edge of the plate because the viscous boundary layer thickness is small, which amplifies the forced convection over the plate because there is a larger effective velocity over the plate at the leading edge.
Degree
thesis:*- Name thesis:degree_name
- M.S.M.E.
- Level thesis:degree_level
- Masters
- Department thesis:degree_department
- Dept. of Mechanical Engineering.
- Grantor
- Baylor University.
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Forslund, Nicholas, 1998-
- Advisor dc:contributor.advisor
-
- McClain, Stephen Taylor.
- ORCID person:identifier.orcid
Subjects
dc:subject × 2Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- No access - Contact librarywebmaster@baylor.edu
- Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2104/11753