Baylor University.
Development and application of high-throughput sample preparation methods for solid matrices.
Abstract
dc:description.abstractThis research presents the development and application of high-throughput sample preparation methods for the analysis of organic and inorganic contaminants from solid samples. The approach presented evaluates conventional methods to identify potential areas of improvement. In this sense, conventional methods serve as a framework for the development of high-throughput sample preparation methods. In general, improvements include expansion of target analyte list thereby increase the environmental applicability, reduction of sample preparation steps, and as a result, reduction of sample preparation time. The analytical bottleneck is often associated with sample preparation, especially in the analysis of organic contaminants from environmental samples. Many environmental analytical chemistry methods can be broken down into one or more sample preparation steps followed by one or more chemical analysis steps. Improvement of historical methods has focused on the development of advance instrumentation (i.e. focusing on the chemical analysis). However, recent efforts have focused on the overall reduction of time and/or steps associated with sample preparation. For example, post-extraction cleanup adsorbents can be incorporated into the pressurized liquid extraction step to perform a selective pressurized liquid extraction (SPLE). SPLE methods significantly reduced sample preparation time, solvent requirements, and waste production. Specific examples presented in this dissertation include: 1) the development and application of SPLE methods for the analysis of organic contaminants from sediments and biological tissues; 2) the development and application of a simplified acid digestion method for the analysis of mercury and selenium in rare samples of Pacific walrus (Odobenus rosmarus divergens) muscle (L. dorsi). These examples illustrate the approach for the development of high-throughput sample preparation methods that have successfully combined techniques into a single method, and/or eliminated post-extraction cleanup steps. The availability of these methods increases laboratory's capacity and preparedness to analyze rapidly large volumes of samples. These methods could find use in routine analysis and monitoring studies of environmental samples, food and pharmaceutical industries, agriculture, toxicology studies, and forensic sciences among others. Lastly, this dissertation discusses a few opportunities that lay ahead for improvement and development in sample preparation.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Level thesis:degree_level
- Doctoral
- Department thesis:degree_department
- Institute for Ecological, Earth & Environmental Sciences.
- Grantor
- Baylor University.
- Year dc:date.issued
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Aguilar Lázaro, Lissette, 1983-
- Advisor dc:contributor.advisor
-
- Usenko, Sascha.
Subjects
dc:subject × 10Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- Worldwide access
- Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2104/9172