Back to search

Universität Bayreuth

Sustainable Energy Conversion in Multigeneration Power Plant Configuration for Climate Change Mitigation

Abstract

dc:description.abstract

The escalating concerns over energy security, environmental sustainability, and the adverse impacts of fossil fuel combustion have intensified the need for innovative and sustainable energy solutions. In this context, a biomass-driven integrated system is proposed in this study. The system comprises of anaerobic digestion, gasification, proton exchange membrane electrolyzer (PEME), Sabatier reactor, solid oxide fuel cell (SOFC), a gas turbine, steam turbine, and organic Rankine cycle (ORC). Biomass feedstocks in the form of animal waste serves as input in the digester and is converted to biogas, and crop residue is converted to syngas in the gasifier. Upgraded syngas and methane from the bio-conversion process is fed to a SOFC-GT topping cycle, with heat recovery bottoming cycles of steam turbine and organic Rankine cycles. To improve the contribution of the ORC to the plant performance, a selection of the best ORC working fluid from six preselected candidates (MM, MDM, cyclopentane, cyclohexane, R1233zd(E), and R600a) is carried out. The proposed system is assessed from thermo-economic, exergo-economic and enhanced exergo-economic viewpoints in Engineering Equation Solver (EES) software. Hydrogen of 0.0023 kg/s with PEME efficiency of 73.73 % is obtained and further used in upgrading the syngas from low heating value of 3.85 to 33.48 MJ/kg. Parametric analysis was performed to ascertain the effect of design parameters on the plant’s performance, and it is indicated that low pressure ratio, high current density, and high turbine inlet temperature are favorable for high energy and exergy efficiency, low levelized cost and low cost of product. An improvement potential analysis based on the enhanced exergo-economic analysis indicates a possibility of recovering 32 % of the total exergy destroyed in the plant. Lastly, a multi-criteria optimization is performed using a multi-objective genetic algorithm (MOGA) in MATLAB to maximize exergy efficiency, minimize the levelized cost of electricity, and the specific cost of product. According to the results of the tri-objective optimization at the optimum point, the plant can attain energy and exergy efficiencies of 55.07 % and 45.08 %, respectively. The total power output is 9.10 MW, with a levelized cost of electricity of 109.02 $/MWh. The specific cost of product is minimized by 16.8 % to 22.52 $/GJ. The net present value of the configuration is increased at optimum, and the break-even point reduced by 16.6 % to 5.43 years. A reduction of 16.7 % is obtained for the levelized emission of CO₂, however, the plant's exergy sustainability index increases from 1.58 to 1.82.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Department thesis:degree_department
Fakultät für Ingenieurwissenschaften
Grantor dc:publisher
Universität Bayreuth
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ogorure, Oreva Joe
Advisor dc:contributor.advisor
  • Brüggemann, Dieter

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • free
Language dc:language.dcterms_iso639_2
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Universität Bayreuth
Base URL
epub.uni-bayreuth.de/cgi/oai2
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
related terms
citation

Ogorure, Oreva Joe. Sustainable Energy Conversion in Multigeneration Power Plant Configuration for Climate Change Mitigation. thesis.doctoral thesis, Universität Bayreuth, 2025. https://doi.org/10.15495/EPub_UBT_00008488