Back to search

University of Birmingham

Bio-mechanical behaviour of articular cartilage: characterisation of surface damage, friction and replacement

Abstract

dc:description.abstract

The progression of cartilage damage has the potential to develop into the joint disease of osteoarthritis. Cartilage repair methodologies involve the implementation of biomaterials, for which the bio-mechanical characteristics should closely align with articular cartilage. To date, the frictional torque of articular cartilage has not been assessed, nor has the coefficient of friction of replacement biomaterials inserted within a defect. Additionally, cartilage damage inducing factors have not been considered for a likely dual effect. Consequently, this thesis presents three novel developments to fulfil the lack of knowledge outlined above. The first novel outcome is the assessment of the dual impact of loading frequency and underlying substrate density, as a replication of bone mineral density, on resulting cartilage damage. The second novel development is a technique to determine the frictional torque of articular cartilage, corresponding to an inserted cartilage replacement biomaterial. The third novel development is a technique to assess the coefficient of friction of a cartilage replacement biomaterial, in line with osteochondral graft surgical procedures. Various approaches have been implemented to include three materials testing machines, Hertzian contact stress analysis and chemical hydrogel manufacture. For this thesis, bovine articular cartilage was modelled for human articular cartilage. The results demonstrate significant cartilage off-bone damage with the multi-factorial effect of a loading frequency of 10 Hz, in combination with an increase in substrate density (p < 0.05). The torque range and characteristics have been identified for which a cartilage replacement biomaterial should adopt, followed by the prospect to assess the coefficient of friction of a biomaterial amongst a defect. The work presented in this thesis has implications on the contribution to osteoarthritis and the manufacture of cartilage replacement biomaterials

Degree

thesis:*
Name dc:type.qualificationname
d_ph
Level dc:type.qualificationlevel
d_ph
Grantor dc:publisher.institution
University of Birmingham
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mahmood, Humaira

Subjects

dc:subject × 2

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
University of Birmingham
Base URL
etheses.bham.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mahmood, Humaira. Bio-mechanical behaviour of articular cartilage: characterisation of surface damage, friction and replacement. d_ph thesis, University of Birmingham, 2020.