Back to search

University of Birmingham

Enhancement of the UK primary standard for absorbed dose for proton radiotherapy

Abstract

dc:description.abstract

With the implementation of proton beam therapy; modern radiotherapy treatments have better outcomes than ever before. Likewise, the development of spatially fractionated radiotherapy treatments have shown tremendous potential in pre-clinical studies for improving patient outcomes. Both of these implementation come at the cost of increasing complexity, providing a greater challenge for both routine quality assurance and primary standard dosimetry. Simultaneously, recent advances in the field of silicon radiation detectors offer a possible solution for high resolution real-time monitoring would would increase confidence in the dosimetry. This thesis describes the application of Silicon Strip Detectors (SSD) and Complementary Metal-Oxide Semiconductor (CMOS) devices to X-ray and Proton beam therapies with the intention to develop new methods of quality assurance and a combined system using the NPL Graphite Calorimeter for proton radiotherapy. A combined system using a large-format CMOS is tested in 6 MV X-ray beams at the NPL, verifying the concept and providing a proof of principle. These measurements produced some unexpected results, which required the development of a model of the Calorimeter in COMSOL, a finite-element simulation software package, to study and better understand the internal heat flow. The developed model can use parameterised beam data acquired by an independent silicon detector (whether CMOS or SSD detectors) as a heat source for coupled simulations of delivered beams. After validating against experimental results, the model was subjected to fields of radiation representative of Pencil beam scanning (PBS), providing confidence in the effectiveness of the NPL Graphite Calorimeter in these radiation beams.

Degree

thesis:*
Name dc:type.qualificationname
d_ph
Level dc:type.qualificationlevel
d_ph
Grantor dc:publisher.institution
University of Birmingham
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Flynn, Samuel Francis
ORCID person:identifier.orcid

Subjects

dc:subject × 1

Rights

Language dc:language.dcterms_iso639_2
eng

Chain of custody

source
Harvested from
University of Birmingham
Base URL
etheses.bham.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Flynn, Samuel Francis. Enhancement of the UK primary standard for absorbed dose for proton radiotherapy. d_ph thesis, University of Birmingham, 2021.